Replacement Of The Connection Cable - Electrolux EGT6142 Notice D'utilisation

Masquer les pouces Voir aussi pour EGT6142:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

12 www.electrolux.com
A
A)
The by-pass screw
• If you change from natural gas G20/
G25 20/25 mbar to liquid gas, fully
tighten the by-pass screw in.
• If you change from liquid gas to natural
gas G20/G25 20/25 mbar, undo the
by-pass screw approximately 1/4 of a
turn.
• If you change from natural gas G20/
G25 20/25 mbar to town gas G130 8
mbar, unscrew approximately 3/4 of a
turn.
• If you change from town gas G130 8
mbar to natural gas G20/G25 20/25
mbar screw approximately 3/4 of a
turn.
• If you change from liquid gas to town
gas G130 8 mbar unscrew approxi-
mately 1 turn.
WARNING!
Make sure the flame does not go
out when you quickly turn the
knob from the maximum position
to the minimum position.
8.4 Electrical connection
• Ground the appliance according to
safety precautions.
• Make sure that the rated voltage and
type of power on the rating plate agree
with the voltage and the power of the
local power supply.
• This appliance is supplied with a mains
cable. It has to be supplied with a cor-
rect plug, able to support the load
marked on the rating plate. The plug
has to be fitted in a correct socket.
• Any electrical component must be in-
stalled or replaced by the Service Force
Centre technician or qualified service
personnel.
• Always use a correctly installed shock-
proof socket.
• Make sure that there is an access to
the mains plug after installation.
• Do not pull the mains cable to discon-
nect the appliance. Always pull the
mains plug.
• The appliance must not be connected
with an extension cable, an adapter or
a multiple connection (risk of fire).
Check that the ground connection is in
conformity with the standard and regu-
lations force.
• The power cable must be placed in
such a way that it does not touch any
hot part.
• Connect the appliance to the mains
with a device that lets to disconnect the
appliance from the mains at all poles
with a contact opening width of mini-
mum 3 mm, eg. automatic line protect-
ing cut-out, earth leakage trips or fuse.
• None of a parts of the connection cable
can not get a temperature 90 °C. The
blue neutral cable must be connected
to the terminal block label with "N". The
brown (or black) phase cable (fitted in
the terminal block contact marked with
"L") must always be connected to the
live phase.
8.5 Replacement of the
connection cable
To replace the connection cable use only
H05V2V2-F T90 or equivalent type. Make
sure that the cable section is applicable to
the voltage and the working temperature.
The yellow/green earth wire must be ap-
proximately 2 cm longer than the brown
(or black) phase wire.
8.6 Building In
min.
450 mm
min.
55 mm
30 mm
470 mm
min.
650 mm
550 mm

Publicité

Chapitres

Table des Matières
loading

Table des Matières