Models K-1100, LX2, K-2300, and LEV110CK/2G
Green Wire (Ground)
Black Wire
Black Wire/White Stripe
Red Wire
Black Wire/Yellow Stripe
See Figure 4 for factory-direct
wiring for 220 volt operation
and Figure 5 for modified wiring
for 110 volt operation.
Figure 9. K-2300 Control Box
|
Installation and Operation Manual
Transformer
Sensor I (Yellow Wire with Blue Stripe)
Sensor Common (Yellow Wire)
Sensor II (Yellow Wire with Red Stripe)
Filling Valve I (Blue Wires)
Filling Valve II (Red Wires)
ENGLISH
Five (5) Status Lights
Red Wires to Filling Valve II
Blue Wires to Filling Valve I
Black Wire to Power (24 VAC)
Yellow Wire with Red Stripe to Sensor II
Yellow Wire to Sensor Common
Yellow Wire with Blue Stripe to Sensor I
Black Wire to Power (24 VAC)
Sensor I
Sensor II