Changing Wiring For 110 Volt Operation; Grounding; Installing The Valve - Jandy Levolor K-1100 Manuel D'installation Et De Fonctionnement

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Jandy Levolor
Electronic Water Leveler
®
Models K-1100, LX2, K-2300, and LEV110CK/2G
3.3
Changing Wiring for 110 Volt
Operation
WARNING
Potentially high voltages in the Levolor
can create dangerous electrical hazards, possibly
causing death, serious injury or property damage.
Turn off power at the main circuit breaker providing
power to the control box to disconnect the control
box from the system. To properly and safely wire the
system, be sure to carefully follow the applicable
requirements of the National Electrical Code (NEC),
NFPA 70 or the Canadian Electrical Code (CEC),
CSA C22.1. All applicable local installation codes
must also be adhered to.
Models K-1100, K-2300, and LEV110CK/2G
Refer to Figures 4 and 5 and do the following:
1.
Cut the splice cap connecting the black/white and
the red wires. See Figure 4.
2.
Connect the red wire with the black wire and
connect to the line side of power. See
Figure 5.
3.
Connect the black/white wire with the
black/yellow wire and connect to the neutral side
of power. See Figure 5.
3.4

Grounding

Connect the green ground wire marked
ground of your electric service or supply panel with a
continuous copper conductor that has green insulation
and is equivalent in size to the circuit conductors
supplying this equipment, but no smaller than no.
12 AWG (3.3mm). Refer to your local codes for the
acceptable grounding wire gauge.
3.5

Installing the Valve

NOTE
Install the valve with the directional water flow
arrow pointing in the appropriate direction.
The directional water flow arrow is located on
the inlet side of the valve.
A 24 VAC solenoid valve will provide water from a
supply line to the pool or spa. You can install the supply
line either before or after the filter at the equipment pad
or on a dedicated line back to the pool.
The K-1100, LX2, and K-2300 use a 1" valve, and the
LEV110CK/2G uses a 2" valve. In addition, Zodiac
recommends an anti-siphon valve (to help prevent
accidental draining of the pool), and an in-line strainer,
which you can purchase from Zodiac.
|
Installation and Operation Manual
1.
2.
control box
®
3.
NOTE The rate can be set up to 30 GPM for the
4.
to the
Figure 10. Valve Flow Controller
Manual
On/Off Lever
Figure 11. Manual Valve Lever
ENGLISH
Connect the 24 VAC water solenoid valve to
the 18-gauge solid-core burial cable using the
supplied grease-filled wire nuts.
Connect the other end according to the model
being installed, using the following instructions:
Models K-1100, LX2, and LEV110CK/2G:
Connect the valve wires to the blue wires in the
control box using wire nuts.
Model K-2300: Connect the wires from Valve
I to the blue wires in the control box using wire
nuts. Connect the wires from Valve II to the red
wires in the control box using wire nuts.
Turn the flow control knob (+) on the top of the
valve (See Figure 10) to set the flow rate to your
specifications.
K-1100, LX2, and K-2300. The rate can be set
up to 130 GPM for the LEV110CK/2G.
Put the manual ON/OFF lever, located just below
the solenoid, in the OFF position, so it will only
open with the electronic water Levolor.
See Figure 11.
ON
Manual Filling
Page 11
Flow Control
OFF
Manual
On/Off Lever
Controlled Filling

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Levolor lx2Levolor k-2300Levolor lev110ck/2g

Table des Matières