Section 2. System Description

Levolor
Models K-1100, LEV110CK/2G, and LX2
®
are computer-controlled devices that detect a low water
condition and automatically replace the water to a pre-
set level. They can be used in all pools and spas.
The LEV110CK/2G is designed for use in large
commercial applications.
Levolor II, Model K-2300, is a dual-fill device that
can maintain the water level in two (2) separate
environments, such as a pool/spa combination or
other dual-equipped application. It can be used in any
situation where a consistent liquid level is desired.
The Levolor kit contains a sensor, a control box, and
a solenoid valve. The Levolor II kit contains two (2)
sensors, a control box, and two (2) solenoid valves.
For more details, see Section 3.1, Materials and Tools.
Sensor
There are three (3) styles of sensors:
1.
Slip Style - installed in static pipe in new pool.
2.
Skim Style - installed in skimmer in existing pool
(also known as Half-moon Style).
3.
Dual Style (Slip on one end/Skim on other end).
NOTE An optional threaded sensor can be installed in
a static pipe in a new pool.
Depending on the model, the sensor comes with 50 to
500 feet of wire at the top and two (2) stainless steel
contacts at the bottom. You can cut off the sensor wire
you do not use.

Control Box

The control boxes for K-1100, LX2 and LEV110CK/2G
have three (3) LED displays: Power, Sensor, and
Filling. The control box for the K-2300 has five (5)
LED displays: Power, Sensor I, Filling I, Sensor II, and
Filling II. For more details, see Section 4. Operation.
The K-1100, K-2300, and LEV110CK/2G are factory
wired for 220 volt operation and require rewiring for
110 volt operation. The LX2 comes in a 220 volt unit
and a 110 volt unit.
Valve
The K-1100, LX2, and LEV110CK/2G require one (1)
valve, and the K-2300 requires two (2) valves.
|
Installation and Operation Manual
Fill Line
Figure 1. K-1100 or LEV110CK/2G Installation
Fill Line
Pump
Return Line
Figure 2. LX2 Installation
The K-1100, LX2, and K-2300 use a 1" valve
(Part # SOL100). It has a pressure rating that cannot
exceed 125 PSI.
The LEV110CK/2G uses a 2" valve (Part # SOL200). It
has a pressure rating that cannot exceed 150 PSI.
2.1
Electrical Specifications
Models K-1100, LX2, K-2300, and LEV110CK/2G
Input: 110 VAC, 50/60 HZ, 0.5 AMPS
220 VAC, 50/60 HZ, 0.5 AMPS
Output: 24 VAC@ 1 AMP
Models K-1100, K-2300, and LEV110CK/2G are
factory wired for 220 VAC service. If available
electrical service is 110 VAC, the power supply
wiring must be changed to operate on 110 VAC as
shown in figures 4, and 5.
ENGLISH
Filter
Check Valve
Solenoid
1" Brass "Y" Strainer
Water
Source
CAUTION
Page 5
Control
Box
Sensor Line
inside Static
Pipe