Wiring - Siemens K44 Duo Manuel D'installation Et Utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 44
8
K44 Duo Installation & User manual

Wiring

24
23
LOCK 1
10
22
21
0V
9
20
EXIT 1
8
19
CONTACT 1
18
17
LOCK 2
10
16
15
0V
9
14
EXIT 2
8
13
CONTACT 2
11
SW1
1
1
12-24V
2
3
2
LED
4
5
3
TAMPER
6
4
7
0V
8
1
9
2
5
10
11
6
"0"
12
7
K44 Duo Installation & User manual
1
Power in, terminal nos 1(+) and 2. 12-24 V.
2
Input for extra LED (red), terminal nos 3 and 4.
10-35 V DC.
3
Tamper switch, terminal nos 5 and 6. Closed when
the housing is closed.
4
Code disabling from external time clock.
Input 1: Close terminal nos 8 and 7.
Input 2: Close terminal nos 9 and 7.
5
Output for alert or duress. Use E7 relay. Connect
between terminal nos 10 and 1(+).
6
Contact for zero (0) opening. Close terminal nos
11 and 7.
7
Output for Door bell (buzzer). Use E7 relay. Con-
nect between terminal nos 12 and 1(+).
8
Input for door contacts. The contact is closed
when the door is closed. Terminal nos 13 and 15
(19 and 21 respectively).
9
Exit button. The door opens on closing terminal
nos 14 and 15 (20 and 21 respectively).
10
Electric locking device. Dashed line refers to locks
with fail-safe function.
11
SW1 push button. Used when choosing password
and erasing memory.