Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Configuration
(Standalone)
Sound-Active
Mode

Automatic Mode

Master/Slave
Mode
Scorpion Storm RGB EU User Manual (Rev. 2 ML)
Set the product in one of the standalone modes to control without a DMX controller.
1.
Connect the product to a suitable power outlet.
2.
Turn the product on.
Never connect a product that is operating in any standalone mode (either Static,
Automatic, or Sound) to a DMX string connected to a DMX controller. Products in
standalone mode may transmit DMX signals that could interfere with the DMX
signals from the controller.
To enable the Sound-Active mode, do the following:
1.
Press <FUNC> repeatedly until Sou shows on the display.
2.
Press <ENTER>.
3.
Select sound sensitivity level S 0~S 9.
The product will only respond to low frequencies of music (bass and drums).
To enable the Automatic Mode, follow the instructions below:
1.
Press <FUNC> repeatedly until Aut, or Sou shows on the display. If Sou shows,
press <UP> or <DOWN> until Aut shows.
2.
Press <ENTER>.
The Master/Slave mode allows a single Scorpion™ Storm RBG EU unit (the "master")
to control the actions of one or more Scorpion™ Storm RBG EU units (the "slaves")
without the need of a DMX controller. The master unit will be set to operate in either
Automatic or Sound Active mode, while the slave units will be set to operate in Slave
Mode. Once set and connected, the slave units will operate in unison with the master
unit.
Configure the units as indicated below.
Slave units:
1.
Press <FUNC> repeatedly until SLA shows on the display.
2.
Press <ENTER> to accept.
3.
Set the DMX address to 001.
4.
Connect the DMX input of the first slave unit to the DMX output of the master unit.
5.
Connect the DMX input of the subsequent slave units to the DMX output of the
previous slave unit.
6.
Finish setting and connecting all the slave units.
Master unit:
1.
Set the master unit to operate in either Automatic or Sound mode.
2.
Make the master unit the first unit in the daisy chain.
Configure all the slave units before connecting the master unit to the daisy
chain.
Never connect a DMX controller to a DMX string configured for Master/Slave
operation because the controller may interfere with the signals from the
master unit.
Do not connect more than 31 slave units to the master unit.