Riello Elettronica Cardin SLX824 Mode D'emploi page 17

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 22
Terminal board connections
1-2 MOT motor power supply
(to change the sense of rotation invert the cables 1 and 2
3-4 ENCODER inputs Bl-Gr for the encoder signal
5-6 ENCODER inputs Gy-Yw for the encoder signal
7
LCK
8
CMN common for all inputs and outputs
9-10 LC-CH2 Potential free contact for the activation of the courtesy light (separate
power supply Vmax=30 Vac/dc: Imax=1A) or the second radio channel. Selec-
tion is carried out on the display LCD1.
CMN common for all inputs and outputs
11
LP 24 Vdc 25 W output for warning lights intermittent activation (50%),
12
12,5 W continuous activation
13
LS 24 Vdc 3 W output for an indicator light
14
CMN common for all inputs and outputs
15
24 Vdc controlled output, powering external loads
16
CMN common for all inputs and outputs
24 Vdc output, powering external loads
17
TA (N.O. contact) opening button input
18
19
TC (N.O. contact) closing button input
20
TAL (N.O. contact) limited opening button input
21
TD (N.O. contact) dynamic button input
22
CMN common for all inputs and outputs
23
TB (N.C./8.2 kΩ) stop button input (The opening of this contact interrupts the
cycle until a new movement command is given)
CP (N.C./8.2 kΩ) safety edge input. Opening this contact will provoke a travel
24
direction inversion during the closing stage and during the opening stage
25
FS (N.C./8.2 kΩ) The opening of this contact will block all movement, until the
All rights reserved. Unauthorised copying or use of the information contained in this document is punishable by law
obstruction has been removed and the pause time has elapsed, due to the safety
device cutting in, the door will then continue moving in the closing direction (only
with automatic reclosing enabled)
FI (N.C./8.2 kΩ) safety and control devices in input (photocells invert the travel
26
direction when an obstruction is detected).
Opening this contact will provoke a travel direction inversion during closure due
to the cutting in of the safety device
27
Inner conductor for radio receiver antenna (if an external antenna is fitted use a
coaxial type cable RG58 with an impedance of 50Ω)
28
Outer conductor for radio receiver antenna
CMN common for the emergency buttons
29
30
EMRG1 (NO contact) emergency manoeuvring button input 1
31
EMRG2 (NO contact) emergency manoeuvring button input 2
CS 1392A
4A
DC 0449
J1
L2
F3
10
F2
4A
J2
F1
10
MOT
ENCODER
1
2
3
4 5 6 7
+
-
Rd
Bk
B1
Signal buzzer "via radio" mode
BC
Battery charger card
LCD1
Display
F1
15A blade fuse
(motor power protection)
(4)
F2
4A blade fuse
(24V circuit protection)
(4)
F3
15A blade fuse
(motor protection during battery operation)
(4)
F4
4A blade fuse
(24V circuit protection during battery operation
(4)
Nota
(4)
These are automotive type blade fuses (max. voltage
(1)
(1)
(2)
(2)
(2)
F4
BC
L1
LC/CH2
8
9
10
11
12
13
)
58V)
ALL UNUSED NC CONTACTS MUST BE JUMPED and consequently the
corresponding security device tests (FI, FS) must also be deactivated.
If you want to activate the FI, FS test both the transmission and receiver parts of
the security devices must be connected to the binding post marked (CTRL24Vdc).
If the test is active there will be a 1 second delay between the command transmission
and movement of the gate/s.
• Switch on the power and make sure that
the indicator LEDs are in the following condition.
- L1 Power on
- L2 Wrong battery connection
Indications on the display
- S1 Indicator for the blocking button
- S2 Indicator for the inverting photoelectric cells
- S3 Indicator for the stop photoelectric cells
- S4 Indicator for the safety edge
- S5 Indicator for the opening button
- S6 Indicator for the closing button
- S7 Indicator for the sequential command
- S8 Indicator for the limited opening button
If the green power on LED "L1" doesn't light up check the condition of the fuses
(2)
and the power cable connection at the transformer primary.
If one or more of the safety indications "S1, S2, S3, S4" flash check the
contacts of the relative security devices and check that the unused safety device
contacts have been bridged.
The indications "S5, S6, S7, S8" change status on the display when the relative
command is activated, eg. pressing the button "TA" will change the status from
'at rest' to 'active'
(white characters on a black background).
Note
The total of the 2 external device outputs must not exceed 10W.
(1)
Note
The (N.C./8.2 kΩ) selection is carried out on the LCD1 display.
(2)
Note
If this LED is "ON" invert the battery power cables immediately.
(3)
Note
If the security device has not been activated the indications on the display
(4)
are at rest. Make sure that when the security device is activated the
status is inverted (black characters on a white background).
B1
14
15
16
17
18
19
20
21
J1
Battery connection
J2
Transformer secondary protection
J3
Emergency enable jumper
MM
Transmitter code memory module
P1
Menu navigation button (
P2
Programming and confirm button (PROG./OK)
P3
Menu navigation button (
R1
Radio frequency module, 433 MHz for series S4XX and S500 transmitters
17
S1
TB FI
FS CP
S3
ON
(3)
OFF
00.000.007
07-06-13
at rest activated
TB
FS
CP
TA
TC
TD
TAL
PROGRAM
TB FI
TA TD
FS CP
TC TAL
00.000.007
07-06-13
15.35
P1
P2
MM
MM
R1
27
28
22
23
24
25
26
)
)
S2
S5
S7
TA TD
TC TAL
S8
S4
S6
15.35
(4)
TB
(4)
FI
FI
(4)
FS
(4)
CP
TA
TC
TD
TAL
LCD1
P3
J3
1 2
1 2
3
3
Pos.1 Pos.2
Disable
J3
Enable
29
30
31

Publicité

Table des Matières
loading

Table des Matières