Important Remarks; Important Safety Instructions - Riello Elettronica Cardin SLX824 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 22

IMPORTANT REMARKS

READ THE FOLLOWING REMARKS CAREFULLY BEFORE PROCEEDING WITH THE INSTALLATION. PAY PARTICU-
LAR ATTENTION TO ALL THE PARAGRAPHS MARKED WITH THE SYMBOL
INSTRUCTIONS COULD COMPROMISE THE CORRECT WORKING ORDER OF THE SYSTEM AND CREATE DANGER
SITUATIONS FOR THE USERS OF THE SYSTEM.
• These instructions are aimed at professionally qualified "INSTALLERS OF ELECTRI-
CAL EQUIPMENT" and must respect the local standards and regulations in force.
All materials used must be approved and must suit the environment in which the
installation is situated.
• All maintenance operations must be carried out by professionally qualified technicians.
• This appliance must be used exclusively for the purpose for which it has been made.
"i.e. for the automation of sliding gates" with a maximum weight of up to 800 kg.
• The geared motor can be positioned either to the left or to the right of the passage-
way. Any non authorised modifications are to be considered improper and therefore
dangerous.
Caution! The installation of both anti-derailment buffers is
absolutely obligatory.

IMPORTANT SAFETY INSTRUCTIONS

It is the responsibility of the installer to make sure that the following public safety
conditions are satisfied:
1) Ensure that the gate operating installation is far enough away from the main road to
eliminate possible traffic disruptions and that the size of the gate, the distance from the
road and the work cycle speed can in no way interfere, causing possible traffic hazards.
2) The motor must be installed on the inside of the property and not on the public side
of the gate. The gates must not open onto a public area.
3) The gate operator is designed for use on gates through which vehicles are passing.
Pedestrians should use a separate entrance.
4) The minimum controls which may be installed are OPEN-STOP-CLOSE, these
controls must be installed at a height between 1,5 and 1,8 m and in a location not
accessible to children. Controls installed externally must be protected by a safety
device inhibiting unauthorised use.
5) The gate must be in full view when it is operating therefore controls must be situated
in a position where the operator can see the gate at all times.
6) At least two warning signs (similar to the example on the right)
should be placed, where they can be easily seen by the public, in the
area of the system of automatic operation. One inside the property
and one on the public side of the installation. These signs must be
indelible and not hidden by any objects (such as tree branches,
decorative fencing etc.). Make sure that the end-user is aware that
children and/or pets must not be allowed to play within the area
of a gate installation. If possible include this in the warning signs.
7) A correct earth connection is fundamental in order to guarantee the electrical safety
of the machine
8) Before carrying out any cleaning or maintenance operations make sure the power
is disconnected at the mains, the motor power cables are disconnected and the
batteries have been disconnected.
9) If you have any questions about the safety of the gate operating system, do not
install the operator. Contact your dealer for assistance.
TECHNICAL DESCRIPTION
- Mains power supply 230 Vac.
- Motor powered with a maximum voltage of 37 Vdc.
- Upper and lower cover in highly resistant shock-proof plastic.
- The reduction unit stator is made of die cast aluminium and contains a never ending
screw and double reduction lubricated with permanently fluid grease.
- Irreversible reduction system with a key-operated manual release mechanism.
- The incorporated electronic programmer contains the power stage, the logic control,
battery charger and the radio receiver decoding module. The power supply is routed
to the electronics card via a separate transformer which is housed in the same
container and is connected to the card by Faston clips.
- The system is fitted with electronic deceleration control which reduces the stress
caused by the gate inertia when it stops.
Accessories
106/CRENY Rack (20 mm x 30 mm) in glass fibre with upper fastening slits (1 m).
106/CRENY1 Rack (20 mm x 30 mm) in glass fibre with lower fastening slits (1 m).
106/SLOAC Rack in galvanised steel (22 mm x 22 mm) 2 m to be welded.
106/SLOAC2 Rack in galvanised steel (12 mm x 30 mm) 1 m with fastening slits.
950/NC8K2L Contact safety edge. Lengths 1,6 to 3,0 m - height 61 mm.
IMPORTANT REMARKS
USER INSTRUCTIONS
Attention! Only for EU customers - WEEE marking.
This symbol indicates that once the products life-span has expired
it must be disposed of separately from other rubbish. The user is
therefore obliged to either take the product to a suitable differential
collection site for electronic and electrical goods or to send it back to
the manufacturer if the intention is to replace it with a new equivalent
version of the same product.
Suitable differential collection, environmental friendly treatment and disposal
contributes to avoiding negative effects on the ambient and consequently health
as well as favouring the recycling of materials. Illicitly disposing of this product by
the owner is punishable by law and will be dealt with according to the laws and
Q
standards of the individual member nation.
During the opening/closing manoeuvre check for correct operation and activate the
emergency stop button in case of danger. During blackouts with a flat battery the gate
can be released and manually manoeuvred using the supplied release key (see manual
release fig. 8). Periodically check the moving parts for wear and tear and grease if
required, using lubricants which maintain their friction levels unaltered throughout time
and are suitable for temperatures of -20 to +70°C.
Eventual repair work must be carried out by specialised personnel using original spare
parts. The appliance is not suitable for continuous operation and may only be operated
using a duty cycle of 70%.
PRELIMINARY CHECKS (fig. 1, pag. 2)
Before starting the installation make sure that the structure which is to be automated
is in good working order and respects the local standards and regulations in force.
To this end ensure that:
- The surface of the sliding gate "A" is smooth and has no protrusions up to a distance
of 2.5 m from ground level. Protrusions on the gate surface which are not greater than
3 mm and have rounded edges are acceptable.
If the surface of the gate is not smooth, the entire height up to 2.5 m from the ground
must be protected by two of the following devices:
WARNING
a) photoelectric cells
AUTOMATIC OPENING
KEEP CLEAR
b) contact safety buffer
- the distance "B" between the fixed parts and sliding parts of the installation must not
exceed 15 mm.
- the runner guide "C", preferably round, should be securely fixed to the ground, com-
pletely exposed and free of any imperfections which could inhibit the correct movement
CHILDREN OR PETS MUST NOT
BE ALLOWED TO PLAY ON OR
NEAR THE INSTALLATION
of the gate.
- when the gate is closed a space of 50 mm "D" must remain for the entire height of
the front part of the gate and a mechanical travel limit "E" must be positioned on the
upper part of the gate.
- The free space "D" can be covered with a rubber anti-crush buffer "F" or better still a
pneumatic or photoelectric contact safety buffer.
- if the gate slides past a fixed structure "G" which has railings or bars leaving open
spaces, it must be protected in one of the following ways:
1. distance "H" greater than 500 mm: no protection required;
2. distance "H" between 500 and 300 mm: wire mesh fencing "I" or punched metal
plating "L" with an opening which does not allow the passage of a 25 mm diameter
sphere "M" must be fitted;
3. distance "H" smaller than 300 mm: wire mesh fencing "I" or punched metal plating
"L" with an opening which does not allow the passage of a 12 mm diameter sphere
"M" must be fitted.
The wires of the mesh "I" must not have a cross-section of less than 2.5 mm
punched metal plating "L" must not have a thickness of less than 1.2 mm. Protection
is not necessary for the area "P" if the fixed structure with railings or bars is over 2.5
m above the ground.
- check the gate components, replace any worn or damaged parts and then lubricate
them.
- using a spirit level "N" check that the castor guide is in square.
- the upper runner guide "O" must have the correct play for the gate and must not inhibit
the gate's sliding action.
- check that a mechanical travel limit "Q" (absolutely necessary) has been fitted in the
opening direction and that it corresponds to the maximum travel distance "P" of the
gate. The travel limit must guarantee anti-derailment and gate stability.
Warning! It is the installer's responsibility to check all critical danger
points, to take action and to install any devices needed to guarantee the
safety of all people using the gate (risk analysis).
14
IMPORTANT REMARKS
. NOT READING THESE IMPORTANT
2
and the

Publicité

Table des Matières
loading

Table des Matières