Production Description And Function; Technical Data - Villeroy & Boch Heating Control Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 12
1

Production description and function

The Heating Control is designed especially for use in bathrooms. The humidity of the air is measured every 30 s
and compared with the previous 4 measurements. If the Heating Control determines that the humidity of the air
has risen by 12 %, the mirror heater is switched on automatically for 10 minutes.
If the Heating Control has been triggered, it engages a battery saving period of 9 minutes during which no
measurements are carried out. Once the battery saving period has elapsed, the sensor starts to measure again.
If a high level of humidity is again measured in the air, the mirror heater is switched on for a further 10 minutes -
otherwise, the mirror heater is switched off.
1.1
Summary
1
Plus key
2
Minus key
3
Sensor
4
Signal LED

1.2 Technical data

Nominal voltage
Battery
Incorrect polarity protection
Interface output
Measuring period
Battery sparing period after triggering
Power consumption in standby
Ambient operating temperature
Humidity
Radio range
Dimensions (mm)
8
3
1
2
3 V +/- 20 % DCV
Voltage spike protection: No
CR 2032 3V
Mechanical: yes
Electrical: no
Serial protocol, remote control 2.4 GHz
Every 30 s
9 minutes
typically 3.3 μA
0 - 50 °C
0 - 100 % non-condensing
typically 15 m indoors
39,8 x 114,9 x 9,7
www.villeroy-boch.com // V 1.0 // 21.02.2017 // Heating Control DE/EN/FR/NL/RU