TROUBLESHOOTING HINTS

An easy way to check that the system is working properly is to disconnect the wiring from the door panel
and to check the monitor directly connected to the EL500SE circuit.
No short circuit will damage the connected units, with the exception of a short circuit between 'CTO' and ' '
monitor or distributor terminals.
Nothing operates.
O
Check the output power supply voltage between ' ' and '+' terminals: it should have 17,5 to
w
18,5Vd.c. If not, disconnect the power supply from the installation and measure again. If it's
correct now, it means there is a short circuit in the installation: disconnect the power supply
from mains and check the installation.
Check that 'D' terminal is not short circuited with ' ' or '+' terminals.
w
Check that 'D' terminal hasn't been changed by 'A' terminal somewhere in the installation.
w
Inappropriate audio level.
O
Adjust the level volumes as shown on page 121. In case of feedback, reduce the audio levels until
w
feedback fade out. If feedback don't dissapears refer to the following hint.
O
Continuous audio feedback.
Check that 'A' terminal is not short circuited with other terminals.
w
Door open function no operates.
O
Remember that this function is only available during call and communication progresses.
w
The CV1 and CV2 terminals for door opening are voltage free outputs. The cable requires a
w
connection depending on whether 12Vdc (page 137 to 148) or 12Vac (page 149) is needed.
Make a short circuit between the 'CV1' and 'CV2' terminals on the EL500SE microprocessor
w
circuit; there should be12V (d.c. or a.c. depending on the type door release installed) between
the terminals on the door release. If so, check the lock release and its wiring.
The system cannot be programmed.
O
Check that the switch number 2 of the SW2 configuration dip switch is set to ON (see page 117)
w
and that the programming steps are correctly followed.
Check that 'D' terminal is not short circuited with other terminals.
w
Some units don't receive calls.
O
Remember that each apartment must have a master unit only. Check that the units are switched on
w
and correctly programmed.