Reset Configuration; Production Data; Off-Line Mode Viewing; Load Control - Ingeteam INGECON EMS Manager Manuel D'installation Et Usage

Masquer les pouces Voir aussi pour INGECON EMS Manager:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 79
INGECON EMS Tools

6.6.3. Reset configuration

To re-stablish the default configuration, press the
Manager's properties' panel. Then, reboot the device (Control bar > Reboot EMS).

6.7. Production Data

The behaviour of the self-consumption system can be viewed using the graphs generated by the application.
Downloading and viewing the logs
1.
Access the plant from the INGECON EMS Tools start screen.
2.
Establish direct connection with the device (Control bar > Connect).
3.
Bring up the Data/Graphs tab in the user interface (Control bar > View > Data/Graphs).
4.
Select the desired day You can view the history profile of all or individually. As a second option, the image
shows the wattmeter and equipment readings.
After viewing the history, the data will be stored in the directory created by the software. In future queries, the
view given will be that from the PC. When the download obtained is for the full day, the day in question will be in a
darker colour.
To download several days at the same time, access the Download Date tab (Control panel > View > Download Date)
and select the desired days. Select Download.
Besides daily viewing, INGECON EMS Tools offers the possibility of viewing downloaded histories (Control bar >
View > Data/Graphs) selecting a range of dates or by using the system´s predefined ranges (daily, weekly, monthly
and annually).
The INGECON EMS Manager has memory allocated for storing the logs of the past 30 days. It is
necessary to download data during this period.

6.7.1. Off-line mode viewing

It is possible to view the log without a direct connection to the INGECON EMS Manager. Instances that have been
downloaded previously will be displayed.
1.
Access the plant from the INGECON EMS Tools start screen.
2.
Bring up the Data/Graphs tab in the user interface (Control bar > View > Data/Graphs).
3.
Select the desired view option.

6.8. Load control

It is necessary to configure the INGECON EMS Manager digital outputs in the following cases:
Presence of controllable loads in the system.
Island operation.
Access the plant in installer mode (see Section "6.4. Plant access in installer mode") and follow the guidelines
below:
1.
Establish direct connection with INGECON EMS Manager (Control bar > Connect).
2.
Access the Loads tab (Control panel > View > Loads).
3.
Configure the settings. See the following sections.
4.
Reboot the device (Control bar > Reboot EMS).

6.8.1. Configuration of controllable loads

Select New, and then Load in the Load Type list, and configure only the parameters shown in the following table.
Parameter
Alias
Load name.
AAX2019IQM01_A - Installation and usage manual
Reset Factory Configuration icon from the INGECON EMS
Description
Ingeteam
DE
EN
ES
FR
IT
PT
53

Publicité

Table des Matières
loading

Table des Matières