Setting Of Diffuser Disc / Electrodes; Pump Pressure - Riello Rg1 Instructions Pour L'installation, L'utilisation Et L'entretien

Table des Matières
Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 23
B
Fig. 11
Remove nozzle-holder assembly (1) after loos-
ing screws (2) and nut (3), remove the small ca-
b l e s ( 4 ) f r o m t h e c o n t r o l b o x a n d t h e
photoresistance (6).
Withdraw the small cables (4) from the elec-
trodes, remove the diffuser disc-holder assem-
bly (10) from the nozzle-holder assembly (1)
after loosing screw (3, fig. 12).
Screw the nozzle (11) correctly and tighten
it as shown in figure.
ATTENTION
During the reassembly of the nozzle-holder
assembly screw the nut (3) as shown in the figure
below.
TIGHTEN WITHOUT MOVING
BACKWARDS TO THE END
4.3 SETTING OF DIFFUSER DISC /
ELECTRODES (
see fig. 12)
ATTENTION
Loosen screw (3) to set the dif-
fuser disc-holder assembly (1)
and loosen screw (4) to set the
electrodes assembly (2).
To have access to the electrodes
carry out operation as described in
chapter "4.2 RECOMMENDED
NOZZLES" (page 6).

4.4 PUMP PRESSURE

The pump leaves the factory set at 12 bar.
To change it act on pump pressure adjust screw (4, fig. 5, page 4).
2303
D5684
3
Fig. 12
B
Fig. 11
0
4.5
– 0.5 mm
2
4
3
D5028
7
GB
S7206
MEASURES
WARNING
MUST BE RESPECTED
±
2.5
0.2 mm
0
1
3
+ 0.5 mm
Table des Matières
loading

Ce manuel est également adapté pour:

363 t13736350

Table des Matières