Regular Maintenance; Troubleshooting - GE Security SB250 Manuel D'installation

Masquer les pouces Voir aussi pour Security SB250:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

• Prolonged interuption of the beam for more than 1 minute (interuption alarm).
For SB450, SB4100 and SB4200 detectors:
• Interupting the beam of just one of the two cells: alarm not triggered.
• Interupting the beam of both cells: intruder alarm.
• Prolonged interuption of both beams for more than 1 minute (interuption alarm).

10. Regular maintenance

To keep good ongoing performance levels, minimal maintenance is required:
• Clean the infrared covers of each module at least once a year (or more often,
depending on exposure to soiling).
• Repeat the final tests (once a year).
• Read the beam cell's received signal values once a year in the same way as when the
equipment was installed (in order to identify any loss of performance).

11. Troubleshooting

Fault observed
The green "Tr ON" LED on the
transmission module is off
The orange "Disq." LED on
the receiver module is
permanently lit
The red "Alarm" LED on the
receiver does not light up
when all the beams are
broken
False alarms
Probable cause
- Incorrect power supply
- No power to the transmitter
module
- Transmitter and receiver
modules using different
channels
- Poor cell alignment
- Object obscuring the beams
- Incorrect power supply to the
receiver
- The beams of the two cells
are not broken simultaneously
(for SB450, SB4100 and
SB4200 detectors only)
- Poor cell alignment
- Incorrect power supply
15
Solution
- Check the power supply
- Check the transmission
power supply
- Set the transmitter and the
receiver to use the same
channel
- Repeat the alignment
procedure
- Clear the paths of the beams
- Investigate the power supply
- Break all the beams at the
same time
- Repeat the alignment
procedure
- Check the cabling and the
cross-sectional area of the
cables used

Publicité