Télécharger Imprimer la page

Installation; Prior To Installation - Jøtul FS 91 Manuel D'installation

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 50
ENGLISH
3.6 External air
The amount of combustion air for Jøtul's products is approximately
25-40 m 3 /h.
A flexible supply hose allowing external air to be fed directly into
the product can be installed as follows:
Through a hole cut where marked in the bottom plate.
Through the hole at the back of the surround.
Suggested installation of the flexible hose for combustion air:
Fig. 2a, through an outside wall
Fig. 2b, through the floor and ground plate
Fig. 2c, through the floor and basement
Fig. 2d, indirectly through an outside wall
44
3.7 Steel chimney
If a top-mounted steel chimney is used, an uninsulated pipe must
run from the insert to approximately 10 mm over the top grate.
Fig. 3
Then fit the steel chimney in accordance with the operating
instructions.

4.0 Installation

NB: Check that the fireplace is undamaged before installation
begins.
NB: The product is heavy! Ensure you have help when positioning
and installing it. Make sure the product does not topple over.
NB: Read the Installation and Operating instructions carefully
before installing the fireplace!
It is recommended that you test-mount the surround to adjust
the insert and flue pipe connection.
Use the acrylic sealant provided for all joints.

4.1 Prior to installation

The basic product comes in two packages:
1. Burn chamber.
2. Concrete units with mounting sections.
NB: Check that there is no visible damage to the product when
you unpack it.
Preparations
Before installation, it is necessary to decide:
Where the smoke outlet is to be located.
Possible use and location of external air supply.
Refer to manuals for installation of the parts.
You will need the following tools to install the product: Spirit
level, ratchet with 10 mm and 13 mm sockets and hex keys with
5 mm socket.

Publicité

loading

Ce manuel est également adapté pour:

Fs 92