REMOVE GROUND STRAP
AND DISCARD. KEEP GREEN
GROUND SCREW
SCREWS
(3)
NEUTRAL
(White)
COVER
HOT
WIRE
RELOCATE GREEN
GROUND SCREW
HERE
GREEN OR
L 1
YELLOW WIRE
N
STRAIN
L 2
RELIEF
BRACKET
3/4", UL
HOT
RECOGNIZED
WIRE
STRAIN RELIEF
4 #10 AWG MINIMUM COPPER
CONDUCTORS OR 120/240V 30A POWER
SUPPLY CORD KIT MARKED FOR USE
WITH DRYERS & PROVIDED WITH
CLOSED LOOP OR SPADE TERMINALS
WITH UPTURNED ENDS (NOT SUPPLIED).
GREEN
GROUND
SCREW
SCREWS
(3)
3 #10 AWG MINIMUM COPPER
COVER
CONDUCTORS OR 120/240V 30A POWER
SUPPLY CORD KIT MARKED FOR USE
WITH DRYERS & PROVIDED WITH CLOSED
LOOP OR SPADE TERMINALS WITH
UPTURNED ENDS (NOT SUPPLIED).
GROUND
STRAP
HOT
STRAIN RELIEF
WIRE
BRACKET
L 1
3/4", UL
RECOGNIZED
L 2
STRAIN RELIEF
NEUTRAL
HOT
(White)
WIRE