If Inputs 2,3 or 4 or even 5, 6, 7 and 8 are used, they
must be within the ATS1290 I/O range. If they are out
of range, they are not available.
3.
If some AD044 inputs are not used, the linked zone
input in the ATS control panel must be programmed
as disabled (default).
4.
If some AD044 outputs are not used, the linked output
in the ATS control panel must not be programmed
(default).
Refer also to the ATS1290 manual for the direct link to the
zone number (control panel).
M
EMORY LOCATION MAP
Every PID device has its own characteristics concerning
related I/O lines or certain functionality of the device.
M
L
EMORY
OCATION MAP FOR
Location
Function
3
Zone types
Supervision
5
outputs
Z
T
ONE
YPE
Input loop
Status ATS control panel
resistance
Double EOL
<20 ohm
Short
47K
Normal
94K
Alarm
> 1Meg ohm
Open
T
S
ECHNICAL
PECIFICATIONS
Bus protocol.........................................GE Interlogix Point ID
Bus voltage........................................................ 12 V or 24 V
External power supply ................... 12/24 V (see Note below)
Current consumption from bus ...................................290 µA
Unit load for DGP ................................................................ 1
Address range .......................................................... 0 to 255
Max Current Outputs ......................................500 mA (each)
Single EOL resistor Inputs ................................ 47 kΩ +/- 5%
Double EOL resistors Inputs........................2 x 47 kΩ +/- 5%
EOL resistors Outputs ................................................. 47 KΩ
Category ........................................................................... I/O
Device type........................................................................ T1
AD044
Decimal values
For example:
0 = All zones are Off
85 = All zones are Single EOL
170 = All zones are Double EOL (default)
For Example:
0 = All Output Supervisions disabled
15 = All Output Supervisions enabled (default)
Status ATS control panel
Single EOL
Short
Normal
Open
Open
A total of 16 memory locations are reserved to configure
the PID devices. Only the first nine are normally user
configurable. This depends on the functionality of the
particular device.
For the AD044 external PID interface only memory locations
3 and 5 matter.
On Memory Location 3, the zone type can be configured for
each input to Single EOL, Double EOL (default) or the zone
can be switched off (the status will always be "Normal").
On Memory Location 5, the output supervision can be
enabled (default) or disabled for each output.
Binary values
Zone 4
Zone 3
Bit 7-6
Bit 5-4
00 = Zone is Off
01 = Single EOL
10 = Double EOL (default)
11 = Undefined
Output 4
Output 3
Bit 3
Bit 2
0 = Disabled
1 = Enabled (default)
Note: The auxiliary power output of closest panel or DGP can
also be used.
3
Zone 2
Zone 1
Bit 3-2
Bit 1-0
Output 2
Output 1
Bit 1
Bit 0