FAR DGV18CH Manuel D'utilisation page 81

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

2. Adjusting the minimum level of the flame
A
B
C
D
(A) Control
handle
(B) Valve
(C) Sealing
ring
(D)
Adjustment
screw
1. Turn the valves to the
minimum level.
2. Remove the valve knob and
place a small screwdriver at the
centre of the valve handle.
3. The correct adjustment is
reached when the flame has a
length of approximately 3 to 4
mm.
– For the butane/propane gas,
the adjustment screw must
be securely tightened.
– Put the control knob back
in its place.
– Make sure the flame does
not turn off quickly when
you turn the knob from
the maximum level to the
minimum level. If this is
the case, remove the control
knob and adjust the gas
flow, then test again once
the adjustment is made.
4. Repeat this procedure for each
of the gas valves.