Filtration
1
OK
5
+
-
6
Heating : This mode acts in the same way as the
automatic mode, but it can also operate via a relay that
controls the temperature. The set point temperature is
determined in this menu and the system operates with
a hysteresis of one degree (for example: if the set point
temperature is 23°C, the system will start up when the
7
Intelligent*: In this mode, the user has two operating
parameters: Select the required water temperature
and the minimum filtration time (minimum two hours
and maximum 24 hours). The filtration will operate
for at least ten minutes every two hours to check the
temperature. The minimum filtration time selected is
divided into twelve sections that are added to its ten
minutes. Example 1: Over twelve hours, the time
Intelligent mode
10 min
1h
0h
2h
28ºC
ON
OFF
10 min
1h
0h
2h
Page 15 of 20
2
+
-
6
+
-
temperature falls below 22°C and shut down only when
it rises above 23°C).
Heating control OFF: The heating operates only during
the filtration periods configured.
Heating control ON: Keeps the filtration on after
is divided between the twelve times a day when the
filtration starts up to check the temperature.
Example 2: (12 hours x 60 minutes) / 12 = 60 minutes
every two hours. This is the filtration and heating
period every two hours. If the programmed filtration
period ends and the required temperature has not
been reached, the filtration and heating remain on until
the required temperature is reached. To minimize the
3h
5h
7h
9h
4h
6h
8h
Intelligent mode operation if the temperature is constant
28ºC
27ºC
3h
5h
7h
9h
4h
6h
8h
Intelligent mode operation if the temperature varies
USE ONLY GENUINE REPLACEMENT PARTS
Control Station
3
7
+
-
T°= 28ºC
11h
13h
15h
10h
12h
14h
16h
27ºC
11h
13h
15h
10h
12h
14h
16h
1
Filtration modes.
4
2
Manual: Allows the filtration process to be turned on
and off manually.
3
Filter cleaning: This mode is used to backwash the
filter.
4
Automatic: In this mode, filtration is turned on
according to the start and end times set in the time
slots. The time slots always operate on a daily basis.
5
Smart*: This mode is based on the automatic mode,
with its three filtration intervals, but the filtration times
are adjusted according to the temperature. This is
done by setting two temperature parameters: the
maximum temperature, above which the filtration
times will be determined by the time slots, and the
minimum temperature, below which filtration will be
reduced to five minutes, the minimum operation period.
Between these two temperatures, the filtration times
will be staggered linearly. The antifreeze mode can be
activated to turn the filtration on if the water temperature
falls below 2°C.
the filtration period has expired if the temperature is
below the set point temperature. When the setpoint
temperature is reached, the filtration and heating stop
and only resume when the next programming period
begins.
number of hours during which filtration operates each
day, this additional time will be deducted from the next
filtration periods occurring during the rest of the day.
(See the chart below).
17h
19h
21h
18h
20h
22h
28ºC
17h
19h
21h
18h
20h
22h
23h
24h
23h
24h