Connecting a Hayward variable-speed pump with digital inputs
When using a Hayward variable-speed pump fitted with digital inputs, bridge the common black wire, connected to terminal (C),
to terminal (7) and follow the connection instructions given in the following table.
You will have to strip the digital cable back 15 cm and cut the orange wire.
Name
Description
V1
Low pump speed (V1)
V2
Average pump speed (V2)
V3
High pump speed (V3)
C
Common
DI4
On/Off
Page 10 of 20
FILTER PUMP
(VSTD)
Brown wire (BRN)
Green wire (G)
White wire (WHT)
Red wire (R)
Black wire (BLK)
USE ONLY GENUINE REPLACEMENT PARTS
Control Station
7 8
L
N
1
3
A1
AUTO
OFF
2
4
A2
= V1 = 1500 rpm by default
= V2 = 2400 rpm by default
= V3 = 3000 rpm by default
= DI4 = On/Off
= C = Common
Terminals
C - 7
1 2 3 C
redoX
pH
Colour
1
Brown (BRN)
2
Green (G)
3
White (WHT)
Black (BLK)
8
Red (R)
Rev. A