Setting the pH/ORP correction time
1
OK
6
1
Setting the pH correction time.
The chemical parameters of the water must be set
manually before the device is started up. If these
adjustments are not made in advance, unwanted
AL3 alarms may be tripped.
2
Enter the password:
3
Select the "Dos. pumps" menu.
4
Select the "pH Pump" menu.
Do not change the default values on the "Pump
alarm AL3" and "Tank signal" menus.
Page 14 of 20
2
+
-
5.1Allows you to set the pH pump to run continuously
(Normal mode).
5.2Allows you to set the pH pump to run intermittently
(Repetition mode).
Caution: if the interval is too long, your pool may
not be protected against acid overdoses and your
equipment may be irreversibly damaged. Too short
an interval may trip unwanted AL3 alarms.
USE ONLY GENUINE REPLACEMENT PARTS
Control Station
3
4
5.1
6
Allows you to set the ON/OFF periods of the
disinfectant pump.
5.2
Rev. A