Safety Notes

Gloves should be worn during installation to prevent
crushing and cutting injuries.
The product may not be used as a holding handle. A
separate handle must be installed.
The hot and cold supplies must be of equal pres-
sures.

Installation Instructions

• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be observed.

Technical Data

Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Thermal disinfection:
10418000 / 10477000 / 34427000 / 38427000 /
39457000 / 10427000 / 36457000: Safety against
backflow
The product is exclusively designed for drinking water!
Fault
Mixer stiff
Mixer dripping
Hot water temperature too low, no
cold water. Instantaneous water
heater starts up when cold water is
selected.
Diverter not operating
4
English
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
max. 70°C
65°C
max. 70°C / 4 min
Cause
- Cartridge defective, calcified
- Cartridge defective
- Hot water limiter incorrectly set
- Crossflow
- Residue
- Water pressure to low
- Diverter defective
Assembly see page 32

Symbol description

Do not use silicone containing acetic acid!
Adjustment (see page 34)
To adjust the hot water limiter. Using a hot
water limiter in combination with a continu-
ous flow water heater is not recommended.
Dimensions (see page 31)
Flow diagram (see page 31)
Rate of flow by 0,3 MPa:
Shower outlet
Tub outlet
Operation (see page 35)
Maintenance (see page 36)
10418000 / 10477000 / 34427000 /
38427000 / 39457000 / 10427000 /
36457000:
The safety device must be checked regularly
according to DIN EN 1717 in accordance
with national or regional regulations (at least
once a year).
Cleaning (see enclosed brochure)
Spare parts (see page 38)
Test certificate (see page 40)
Remedy
- Exchange cartridge
- Exchange cartridge
- Set hot water limiter
- Exchange cartridge
- Clean converter / grease O-rings
- Increase water pressure
- Exchange diverter

Publicité