Operating Instructions; Checking For Leaks; Operating Main Burners - Backyard Grill GBC1870W-C Manuel D'utilisation

Masquer les pouces Voir aussi pour GBC1870W-C:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Checking for Leaks

Burner Connections
1 .
Make sure the regulator hose and valve connections are securely fastened to the burner and the
tank .
2 .
Visually check the connection between the burner/venturi tube and orifice .
3 .
Make sure the burner/venturi tube fits over the orifice .
W WARNING: Failure to inspect this connection or follow these instructions
could cause a fire or an explosion which can cause death, serious bodily
injury or damage to property.
4 .
Please refer to diagram for proper installation (Figure 1) .
5 .
If the burner/venturi tube does not rest flush to the orifice, as shown, please contact
1 .800 .694 .0013 for assistance .
Tank/Gas Line Connection
1 .
Make 2-3 oz . of leak detection solution by mixing one part liquid dishwashing soap with three
parts water .
2 .
Make sure control knobs are in the " OFF" position (Figure 2) .
3.
LP: Connect LP gas tank per "Installing LP Gas Tank" section .
NG: Connect NG main line per "Installing Natural Gas Line" section .
4.
LP: Turn LP gas tank valve to "OPEN ."
NG: Turn "ON" natural gas main valve .
5 .
Spoon several drops of solution, or use a squirt bottle, at all "X" locations (Figures 1 and 3) .
a. LP: If any bubbles appear, turn LP gas tank valve to "CLOSED," reconnect and re-test .
NG: If any bubbles appear, turn natural gas main valve "OFF," reconnect and re-test .
b. LP: If you continue to see bubbles after several attempts, turn LP gas tank valve to "CLOSED"
and disconnect LP gas tank, per "Disconnect LP Gas Tank" section . Contact 1 .800 .694 .0013 for
assistance .
NG: If you continue to see bubbles after several attempts, turn natural gas main valve to "OFF ."
Disconnect natural gas line and contact 1 .800 .694 .0013 for assistance .
c. LP: If no bubbles appear after one minute, turn LP gas tank valve to "CLOSED," wipe away
solution and proceed .
NG: If no bubbles appear after one minute, turn natural gas main valve to "OFF," wipe away
solution and proceed .
First Use
1 .
Make sure all labels, packaging and protective films have been removed from the grill .
2 .
Remove manufacturing oils before cooking on this grill for the first time by operating the grill for
at least 15 minutes on (HIGH) with the lid closed . This will "heat clean" the internal parts and
dissipate odors .

Operating Main Burners

Lighting
W CAUTION: Keep outdoor gas cooking appliance area clear and free from
combustible materials, gasoline and other flammable vapors and liquids.
W CAUTION: Do NOT obstruct the flow of combustion and ventilation air.
W CAUTION: Check and clean burner/venturi tubes for insects and insect nests.
A clogged tube can lead to a fire.
W CAUTION: Attempting to light the burner with the lid closed may cause an
explosion.
1 .
Open lid .
2 .
Check for obstructions of airflow to the burners . Spiders, insects and webs can clog the burner/venturi tube . A clogged burner tube can
lead to a fire .
3 .
All control knobs must be in the " OFF" position (Figure 2) .
4.
LP: Connect LP gas tank per "Installing LP Gas Tank" section .
NG: Connect NG main line per "Installing Natural Gas Line" section .

Operating Instructions

Figure 1:Main Burners
LP Gas
Connection
Figure 2: Side Burner
Valve Soft Pipe
Connection
LP Gas Valve
with Orifice
Figure 3
Figure 4
X
X
X
X
16
Burner/
Venturi Tube
LP Gas Valve
with Orifice
LP Gas
Connection
Burner/
Venturi Tube
X

Publicité

Chapitres

Table des Matières
loading

Table des Matières