d) avoid damaging the mounting bore
e) Avoid loads on the sharpening surface
f) store grinding wheels flat or perpendicularly, keep dry, protected from frost and at a constant and
medium temperature.
g) Keep the grinding wheels in their original packaging or in special containers and on shelves.
26. Electrical instructions
The tool is fitted with a two-pronged plug. Do not attempt to modify the plug, as it could result in a
safety hazard (electric shock hazard) and void the guarantee.
3.3- Safety warnings regarding the use
Important notice! Observe any national safety regulations regarding installation, operation and
maintenance.
1. Become familiar with the controls and the proper use of the equipment.
2. The use of this product by children is forbidden.
3. Only well-instructed adults should operate the product. This product is not intended for use by
persons (including children) with reduced physical, sensory or mental capabilities, or lack of
experience and knowledge, unless they have been given supervision or instruction concerning use of
the product by a person responsible for their safety.
4. Use only accessories with a permissible speed at least as high as the no-load speed of the machine.
5. Do not use tool if damaged, eccentric or vibrating.
6. Do not use damaged, cracked, eccentric or vibrating wheels.
7. Never seize or touch the wheel during operation
8. Position power cable in a way that it is not trodden on or damaged during use.
9. If the power cable is damaged, it must be replaced by the manufacturer, its after sales service or a
person with similar qualification in order to avoid any danger.
If the power cable or extension cord is damaged or cut during operation, immediately disconnect plug
from its main power source. Do not touch the cable or extension cord before unplugging from main
power.
10. Grinding may create dust and projection of debris. Wear appropriate protective equipment (dust
mask, safety goggles...).
Use dust extraction device when available, and ensure that it is properly connected and used.
11.
Residual risks
Even when the tool is used as prescribed it is not possible to eliminate all residual risk factors.
The following hazards may arise in connection with the tool's construction and design:
a. Damage to lungs if an effective dust mask is not worn.
b. Damage to hearing if effective hearing protection is not worn.
c. Health defects resulting from vibration emission if the power tool is being used over longer period
of time or not adequately managed and properly maintained.
d. Bruising hazard if the grinding wheel is touched while in operation.
e- Exposure to electricity by using a non-standard defective electrical connection lines.
12. WARNING!
This machine produces an electromagnetic field during operation. This field may under some
circumstances interfere with active or passive medical implants. To reduce the risk of serious or fatal
injury, we recommend persons with medical implants to consult their physician and the medical
implant manufacturer before operating this machine.
13. The declared vibration total value has been measured in accordance with a standard test method
and may be used for comparing one tool with another, especially applicable when other tool as same
construction and is operated with same power supply.
The declared vibration total value may also be used in a preliminary assessment of exposure.
14. Warning: The vibration emission during actual use of the power tool can differ from the declared
total value depending on the ways in which the tool is used.