Electrical Connection - Pentair AZUR SWIMMEY Manuel D'installation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 6
8. Shift valve handle to position "Filtration" and start
the pump
7. MAINTENANCE
The strainer basket should be daily removed and
cleaned. Never operate the pump without its strainer
basket. The filter needs no maintenance.
CAUTION: ALWAYS DISCONNECT THE POWER SUPPLY
TO THE PUMP BEFORE SERVICING
8. WINTERIZING
Protect the pump, the filter and the piping from
freezing. Open the drain (3) and shift the valve handle
to "Backwash". Remove the pump to a dry and warm
room. Do not wrap the motor with plastic covering as
condensation may damage the pump.
In installations where the pump can not be drained, a
40% propylene glycol, 60% water solution will protect
to -46°C. Do not use other anti-freeze solutions, these
are all highly toxic and will damage the pump.

9. ELECTRICAL CONNECTION

The electrical motor must be wired by a professional
according to the installation instructions of your local
electricity company.
CAUTION: AT THE INSTALLATION OF THE PUMP A
MOTOR SECURITY HAS TO BE FORESEEN WHICH
SHOULD BE IN ACCORDANCE WITH THE NOMINAL
POWER OF THE MOTOR.
Monophase
Swimmey -8M
Swimmey -10M
FreeFlo - 10M
Swimmey -12M
FreeFlo - 12M
Swimmey -15M
FreeFlo - 15M
Swimmey -19M
FreeFlo - 19M
The supply voltage should be within ± 5% of the
design voltage, specified on the nameplate of the
motor. Single-phase motors should be connected at the
terminals as indicated in the junction box.
CAUTION: MAKE SURE THAT YOU INTERRUPT THE
POWER SUPPLY TO THE CABLES WHEN CONNECTING
THE CABLES OF THE PUMP
Every motor must be permanently grounded.
An earth safety or circuit breaker switch with a
sensitivity of 30mA should always be included at the
installation. The wiring size and the type of fuses (min-
imum H05RN-F) should be selected in accordance with
the motor capacity.
CAUTION: CONNECTIONS WHICH ARE NOT CONFORM
P1
0.43 kW / 230 V
2.2 A
P2
0.18 kW / 230 V
P1
0.48 kW / 230 V
2,35 A
P2
0.25 kW / 230 V
3,0 A
P1
0.55 kW / 230 V
2,5 A
P2
0.37 kW / 230 V
3,0 A
P1
0.65 kW / 230 V
3,0 A
P2
0.50 kW / 230 V
4,2 A
P1
1.10 kW / 230 V
4,5 A
P2
0.75 kW / 230 V
5,5 A
TO THE ABOVE-MENTIONED SAFETY INSTRUCTIONS,
ARE NOT COVERED BY THE WARRANTY.
10. REPLACING THE SAND
Disassemble the drain (3) and let the water flow
out. Remove the sand. The sand in the filter must be
changed every 5 years.
11. TROUBLE SHOOTING
Pump will not prime
1. No water in strainer pot
2. Strainer pot is not tight
3. Damage lid O-ring
4. Water level is below skimmer
5. Strainer basket or skimmer basket is clogged
6. Closed valve in piping system
7. Air leak in suction line
Motor does not turn
1. Power switch is off
2. Circuit breaker has tripped
3. Pump is off-mode of a timer controlled circuit
4. Motor terminal connections are incorrect
5. Motor shaft is locked by bad bearing
6. Impeller is locked by debris
Low flow-high filter pressure
1. Filter is dirty
2. Restriction in return line
Low flow-low filter pressure
1. Strainer basket or skimmer basket is clogged
2. Clogged impeller
3. Air leak in suction line
4. Restriction in suction line
Noisy pump
1. Air leak in suction
2. Foreign matter in pump housing
3. Cavitation
12. Warranty
Pentair Water is not responsible for transport damage.
In case of damage notify carrier immediately.
Warranty period:
Limited warranty: 2 years
3

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Azur freeflo

Table des Matières