en - Operating and Installation Instructions Q node 5

Technical description

Network nodes Q node 5 receive and process data from consumption metering devices (maximum 500) within the Q AMR system. Several
network nodes (maximum twelve) form a network. There are different types of network node for the different application cases. All types can
be combined with one another in a network.
Components Q node 5
The network node Q node 5 is made up of the following components:
Power supply:
Memory
500 measuring devices
Backup battery
Transmitter and receiver are used for recording the data from con-
sumption metering devices and forwarding these to other network
nodes in the same network. The data memory contains the meas-
uring data from the consumption metering devices. It is protected
against temporary power failure, for instance during replacement of
the main battery, by the backup battery. Local network readout can
take place via the M-Bus interface (an M-Bus load).
Keys
The network node has 3 keys with the following functions:
DISPLAY Key (10) for switching over the display and acknowledging faults.
MODE
Key (9) for switching installation mode on or off. If an extended mode is active, this key is pressed to return to the standard mode.
RESET
Recessed key (7) for triggering a network reset (interruption of all connections between the network nodes).

Display levels

-
Current
operating mode (Mode)
A
Alternating Q node 5 number (primary
address) and network number
B
Number of Q node 5 in the network
C
Number of consumption metering
devices in the network
D
Remaining capacity of the main bat-
tery of the Q node 5 in percent
E
Fault codes (three groups)
14
Battery
M-Bus
(Slave)
IrDA
(optical)
FOM5-00AM-DES-RNN5
Parts and operating elements
(1) Plug connector for M-Bus
service connection
(2) Plug connector for extension
module
(3) Plug connector for voltage
supply DC 3.6 V
(4) LED for network voltage
display with external supply
(only lit during mains supply)
Technical data Q node 5
CE conformity
Protection rating
Protection class
Electromagnetic compatibility
Interference resistance:
Emitted interference:
Security of IT equipment
Rated voltage
Service life
Main battery (with factory settings)
Backup battery
Ambient conditions
during transport
in non-ventilated containers
in ventilated containers
Relative air humidity
during storage
Relative air humidity
during operation
Relative air humidity
Weight
(5) Plug connector for backup
battery DC 3.6 V
(6) Connector outlet
(7) Reset key (recessed)
(8) Display
(9) Serial number
(10) Operating mode key
(MODE, red)
(11) Display switchover key
(DISPLAY, blue)
(12) IrDA interface (opti-
cal)
IP 20
II
EN 301 489
EN 300 220-1
EN 60950
DC 3.6 V
> 5 years
> 10 years
-25...+70 °C
-25...+40°C
max. 95% at 40°C
-5...+45 °C
max. 95%
...+55 °C
max. 95%
gross
0,760 kg
net
0,648 kg