Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 16
EN
SYMBOLS
Read the instructions.
Approved in accordance with
the relevant directives.
Recycle discarded product
in accordance with local
regulations.

TECHNICAL DATA

Operating voltage
Basic model
Max operating temperature
Lowest installation temperature
Minimum bending radius
Output
10 W/m at +10°C for routing on metal tube
Size
Maximum cable length:
External routing: 100 metres - (max 10 A)
Internal routing: 60 metres - (max 10 A)
DESCRIPTION
The product consists of a heating cable and a
2 m long connecting rubber cable with plug.
It is connected to a 230 V power point. The
heating cable is designed to automatically limit
the heat when necessary. There is no risk of
overheating the heating cable. The product has
an IP68 rating.
1.
Outer sheath
2.
Reinforcement, tinned copper
3.
Insulation TPE
4.
Self-limiting core material
5.
Wire, tinned copper
FIG. 1
APPLICATIONS
The product can be used for a wide range of
10
230 VAC
85 CM (SS 4242411)
65°C
-30°C
35 mm
8.0 x 5.7 mm
applications:
• Antifreeze protection of pipes, external
routing
• Antifreeze protection of pipes, internal
routing
• Water meter
• Caravan
• Greenhouse
• Compost
ASSEMBLY
INSTALLATION
Pay attention to the following
before installation
The maximum connected length for
internal routing is 60 m, and for external
routing 100 m.
The maximum fuse is 10 A.
The maximum permitted pressure for
installation in water pipes is 8 bar.
The heating cable is intended for
temporary installations.
The heating cable should always be
connected via a residual current device.
The heating cable should only be covered
with material that can withstand at least
+ 65°.
The rubber cable cannot be replaced – if
damaged, discard the complete heating
cable.
Installing external antifreeze
protection
Fasten the cable with electrical tape to the
pipe or part you want to protect from freezing.
Always insulate the pipe or part to retain the
heat. If the cable is too long, or to increase the
effect, you can also wind the cable round the
pipe or part in a spiral. Wind the cable round
water meters or large pipe fittings. The cable
can be crossed over itself, neither the cable nor
the part will over heat.

Publicité

Table des Matières
loading