Les langues disponibles

framing
EN
NON-COMBUSTIBLE
MATERIAL
65 7/8"
167.3cm
88"
223.5cm
ENCLOSURE
55 1/4"
HEIGHT
140.3cm
* Within the appliance enclosure a 11" (279mm) clearance between the top of the vent pipe and combustible material is
required. All other clearance, including where the vent exits the enclosure are subject to 1 1/2" (38mm) to the sides and
bottom and 4 1/2" (114mm) to the top for horizontal and 1" (25mm) for vertical.
note:
The fi restop assembly provided must be used when the vent pipes pass through any wall, fl oor, or ceiling.
28
W415-2363 / A / 11.01.19
11"
279mm
STEEL STUD
FRAMING
41 7/8"
106.4cm
4 1/2"
114mm
0" IF NON-COMBUSTIBLE
FINISHING MATERIAL
IS USED SUCH AS
BRICK AND STONE.
1 1/2"
38mm
FIRESTOP
ASSEMBLY
71 1/2"
181.6cm
2"
51mm