Lenze E82ZWBRE Instructions De Montage page 45

Contacteur de frein électronique
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

0
Connection variant 1:
Z1
Standard I/O function module
The internal voltage source of the function module supplies the digital output.
Control of the brake switch via the digital output of the function module.
1
Connection variant 2:
Z1
Application I/O function module
The internal voltage source of the function module supplies the digital output.
Control of the brake switch via the digital output of the function module.
2
Connection variant 3 (only with 8200 motec, variant V152 or V153):
Z1
Function module
The internal voltage source of the function module supplies the digital output of the
motec.
Control of the brake switch via the digital output of the motec.
Note:
Instead of using the internal voltage source of the function module, you can also supply
the digital output of the motec via an external 24 V DC voltage source.
Terminal data
Flexible
With wire end
ferrule
EDK82ZWBRE DE/EN/FR 7.0
Conductor cross−section
2
[mm
]
0.5 ... 1.5
20 ... 16
l
Electrical installation
Wiring in the 8200 motec
[AWG]
[Nm]
0.5 ... 0.6
Tightening torque
[lb−in]
4.5 ... 6.2