TEMPERATURE SENSOR :
The temperature sensor is used to monitor the temperature
automatically according to the pre-set temperature and maintain
the room temperature constantly. The installation height of the
sensor should be about 1.3 –1.5 m from ground. Please drill
a hole, and then nail down the sensor in the steam room, pull
the sensor wire through the conduit then connect to the circuit
board.
COVER
SENSOR WIRE
WALL
Caution: The control wire and temperature wire should not be
parallel to or intersect with the power wire. The temperature
sensor should not be installed on the side of the wall which is
behind the door and the controller should not be installed in any
moist place.
4. INSTALLATION OF PIPE LINE
Caution:
customer access, the water inlet valve must be easy to
access for emergencies.
• The solenoid valve can endure maximum 0.2MPa water
pressure. To protect the solenoid valve from extremely high
water pressure, please turn down the inlet slightly or install
water pressure reducer valve.
• Please dredge and clean the pipe before installation.
steam pipelines should be installed with a slight angle so
steam head.
Fig.1
Steam generator
Auto drain valve
WATER INLET:
Firstly, connect the water magnetizer (if applicable) to the water
inlet solenoid valve.
the other side of the water magnetizer and the water supply
pipeline. Do not connect to metal water supply pipeline directly
which may damage the water inlet valve. Only use cold water
TEMP SENSOR
supply.
STEAM OUTLET:
sheet of the product) copper pipe to connect the steam head
and the steam outlet pipe of the generator. The pipe should be
less than 3 meters long and minimize the number of elbows,
otherwise heat isolating methods should be implemented.
STEAM HEAD: The steam head should be about 300mm from
the ground and at least 150mm from user's seats. Please apply
head, and then screw the steam head on to the steam pipe
DRAIN PIPE:
Steam pipe
Flexible stainless steel
hose
Valve
Water supply
Water magnetizer
22
• The steam pipeline must be copper pipes, all other material
such as plastic, acrylic should not be used since they
cannot endure 150°C or higher temperature.
• All inlet and apertures should be sealed to prevent any
may cause serious scald and damage the steam room.
A separate draining pipe is required to drain water to the
drainage. All inlet water pipes and steam pipelines should
be built according to the National Standard (refer to Figure
1) and this should be done before sealing the wall.
Steam head
A
Ø32
300 mm
Aromatherapy
Reservoir
Apply
silicone
here