COMMUNICATOR RESET / UPDATE / NETWORK DATA USAGE

Factory Defaults Reset

You can reset the programming options for the Communicator to the factory settings by installing the hardware jumper. Perform
the following steps to reset the Communicator:
NOTE: Two pins require a jumper in order to reset the hardware values.
1. Remove panel front cover.
2. Locate the AUDIO/DEFAULT five pin connector in the middle of the Communicator board. On the PC1616/1832/1864 panels
pins 4 and 5 are on top. (See Figure 3). On the PC9155 panel, pins 4 and 5 on right. See Figure 5).
3. Apply a jumper to short the hardware default pins 4 and 5 together.
4. Remove all power from the panel and then apply power to the panel. Wait until the two green LEDs on the Communicator begin
flashing rapidly. (The Green LEDs will continue to flash as long as the hardware jumper is connected).
5. Remove the jumper from the hardware default pins 4 and 5. (Green LEDs will stop flashing).
NOTE: Your Communicator has now been reset to the factory default values.

Firmware Update

The firmware of the device can be updated over GPRS or Ethernet. (Remote or Local updating).
• When the firmware update begins, all LEDs are ON.
• During the firmware update process, the LEDs will be cycled individually in a chaser pattern.
• After a successful update the unit will automatically restart.
• Should the update fail, all 4 LEDs will flash ON, then OFF together at 1 second intervals.
• If the firmware update fails, restart the unit. In the event of consistent update failures, contact your dealer.

Network Data Usage

PACKET TYPE
Init
Communicator to Receiver
Init ACK
Receiver to Communicator
SIA -Single Event
Communicator to Receiver
SIA -6 Events
Communicator to Receiver
SIA ACK
Receiver to Communicator
Contact ID Event
Communicator to Receiver
NOTE: With encryption and supervision on, all packets are 149 bytes.
DIRECTION
BYTES
101 Bytes
74 Bytes
124 Bytes
149 Bytes
77 Bytes
70 Bytes
PACKET TYPE
Contact ID ACK
Heartbeat 1
Heartbeat 1 ACK
Heartbeat 2
Heartbeat 2 ACK
Encryption and Supervision Enabled Both Directions
9
Table 6: Network Data Usage
DIRECTION
Receiver to Communicator 49 Bytes
Communicator to Receiver 101 Bytes
Receiver to Communicator 74 Bytes
Communicator to Receiver 60 Bytes
Receiver to Communicator 60 Bytes
149 Bytes