(5) Ventilation fan
(6) Fixation screw
(7) Service-lid
(8) Focus-screw
(9) Objective lens
Sensitivity
15
Fuse:
T 2 A, 250 V
16
17
(10) Blackout-socket
(11) DMX-In socket
(12) DMX-Out socket
(13) DIP-switches
(14) Microphone
(15) Sensitivity-control
(16) Fuseholder
(17) Power supply

INSTALLATION

Installing/Replacing the lamp

For the installation, you need one EFR 15 V/150 W GZ-6,35 lamp.
Microphone
Setting the DMX-
DIP-switch no.
1
2
starting address:
Projector number
1
2
Starting address
& channels
On
Projector 1 - channel 1
Off
Off
On
Projector 2 - channel 2
Off
On
Projector 3 - channel 3
Off
On
Projector 4 - channel 4
Off
On
Projector 5 - channel 5
Off
Power supply:
230 V AC, 50 Hz ~
DANGER TO LIFE!
Only install the lamp with the device switched off!
Unplug from mains before!
The lamp has to be replaced when it is damaged
or deformed due to the heat!
14
13
LIGHTING CONTROL
PROTOCOL DMX-512
3
5
6
7
8
9
4
4
8
16
32
64 128 256
XLR occupation:
1: Ground
2: Signal (–)
3: Signal (+)
CAUTION!
18
Blackout
DMX In
DMX Out
10
11
12