the previously selected characters. Put the button on the telecamera in the different positions to move the
characters in the desired position. Once the position has been defined, press again the button to go back to
the previous menu. To quit the menu select END.
MOTION – MOTION DETECTOR
This function allows to detect movements in the camera captured images. In this special screen, the scene
is split up into sectors, that can be activated by the user. Therefore it is possible to make some specific
points sensitive to movement (up to 4) and exclude other ones. For example, if the scene includes a door
and a window, the alarm can be activated only by a door movement, excluding any movement of the
window. In case of sudden movements (i.e. when the door opens) the operator will see a signal on the
screen. This will have the specification that was set up in correspondence to the sensitised area where the
movement happened.
Select ON to access to the following submenu:
SELECT
DISPLAY
SENSITIVITY
COLOR
TRANS
ALARM
DEFAULT
RETURN
Option
SELECT
DISPLAY
SENSITIVITY
COLOR
TRANS
ALARM
DEFAULT
ALARM - ALARM MOTION MANAGEMENT
VIEW TYPE
OSD VIEW
ALARM OUT
TIME
RETURN
24
MOTION
AREA1
ON
■■■■■█■■■64
GREEN
1. 00
RET
Value
AREA1  AREA4
ON  OFF
0  100
GREEN  BLUE 
WHITE  RED
0.00  1
/
/
ALARM
ALL
ON
ON
■■█■■■■■■3
RET
The scene is split up into areas that can be activated by
the user. Select each area to be set and confirm with the
option DISPLAY (see below)
Select this option to enable (ON) or disable (OFF) motion
detection for previously selected areas.
This function allows to increase or decrease the motion
detector sensitivity.
Use the camera joystick to select a value from 0 (low
sensitivity) and 100 (high sensitivity).
This function allows to define the perimeter color of the
selected area
Not available
Alarm motion signals management (see below)
It allows to restore the default settings.