Panasonic WH-ADC0916G9E8 Mode D'emploi page 7

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 16
Operation/settings to be done only by the authorised dealer/specialist.
Dealer
Operation/settings to be done by the authorised dealer/specialist or user.
User
6
Backup Heater For Tank
To activate backup heater during tank operation.
• Do not use the system during sterilisation in order to prevent scalding with hot water, or overheating of shower.
• Ask an authorised dealer to determine the level of sterilisation function field settings according to the local laws and regulations.
7
Sterilisation
To sterilise the water tank, if required.
Note: If NO is selected, menus 8 to 10 are skipped.
8
Sterilisation Day & Time
To set timer for sterilisation.
(Only once a week. Operates even under a standby condition)
9
Sterilisation Temperature
To set the temperature of sterilisation.
10
Continuation of Sterilisation
To maintain heating temperature in order to complete the sterilisation.
11
Base Pan Heater
To select whether or not to connect to the optional base pan heater.
Note: If NO is selected, menu 12 is skipped.
12
Base Pan Heater type
Type A - The base pan heater activates only during deice operation.
Type B - The base pan heater activates when outdoor ambient
temperature is 5 °C or lower.
13
*
1,
*
2
Cool Outdoor Temperature setting
To set the outdoor ambient temperature for the AUTO mode to
change from HEAT to COOL.
14
*
*
Heat Outdoor Temperature setting
1,
2
To set the outdoor ambient temperature for the AUTO mode to
change from COOL to HEAT.
15
Dry Concrete
During construction to dry the concrete under a preset temperature.
Do not use this menu for any other purposes and in period other than
during construction (Refer to Information page).
User
Control panel preparation
1 Press
.
2 Press
or
to set the current day.
3 Press
to confirm.
4 Repeat steps 2 and 3 to set the current time.
Note:
• The current day and time need to be set in cases below:
- When the power is turned on for the first time.
- A long time has elapsed since the power was turned on the
last time.
• The current time that has been set will be the standard time for
all the timer operations.
*
The system is locked to operate without COOL mode. It can be unlocked only by authorised installers or our authorised service partners.
1
*
Only displayed when COOL mode is unlocked (Means when COOL mode is available).
2
F569865-SS1114-0.indb 7
F569865-SS1114-0.indb 7
Caution Indicator (Tank Temperature above 60 °C)
Process Black
Process Black
YES
YES
NO
YES
YES
NO
Monday ~
Monday
Sunday
12:00
0:00 ~ 23:50
65 °C
40 °C ~ 65 °C
5 minutes ~
10 minutes
1 hour
NO
YES
NO
A
A
B
15 °C
5 °C ~ 25 °C
10 °C
5 °C ~ 25 °C
-
1 day ~ 99 days
7
08/01/2015 12:44:38 PM
08/01/2015 12:44:38 PM

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Wh-ux09fe8Wh-ux12fe8Wh-ux16fe8Wh-ud09fe8Wh-ud12fe8Wh-ud16fe8

Table des Matières