Allowed / Not Allowed Fuels; Lighting - Nordica NORMA - S IDRO DSA Instructions Pour L'installation, L'utilisation Et L'entretien

Masquer les pouces Voir aussi pour NORMA - S IDRO DSA:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

NORMA - S IDRO DSA
Their size is established by regulations regarding the subject. Ask for information from a chimneys weep. The openings must be protected
with grills and must never be blocked up. An extractor hood (suction) installed in the same room or in a neighbouring one causes a
depression in the environment. This causes the leakage of burnt gas (dense smoke, smell); it is therefore necessary to ensure a greater
flow of fresh air.
The depression of an extractor hood can, in the worst case scenario, transform the flue of the thermo-product into an external
air inlet, re sucking the flue gases into the environment with very serious consequences for persons.

8. ALLOWED / NOT ALLOWED FUELS

Allowed fuels are logs. Use exclusively dry logs (max. content of water 20%). Maximum 3 logs should be loaded. The pieces of wood
should have a length of ca. 20-30 cm and a maximum circumference of 30-35 cm.
Compressed not worked-out wood briquettes must be used carefully to avoid overheating that may damage the device, since
these have a very high calorific value.
The wood used as fuel must have a humidity content lower than the 20% and must be stored in a dry place. Humid wood tends to burn
less easily, since it is necessary a greater quantity of energy to let the existing water evaporate. Moreover, humid content involves
the disadvantage that, when temperature decreases, the water condensates earlier in the hearth and therefore in the stack causing a
remarkable deposit of soot with following possible risk of fire of the same.
Fresh wood contains about 60% of H
It is necessary to place this wood in a dry and ventilated place (for example under a roofing) for at least two years before using it.
Besides others, it is not possible to burn: carbon, cuttings, waste of bark and panels, humid wood or wood treated with paints,
plastic materials; in this case, the warranty on the device becomes void.
Paper and cardboard must be used only to light the fire.
The combustion of waste is FORBIDDEN and would even damage the appliance and the flue, causing health damages and claims by
the neighborhood owing to the bad smell. The wood is not a fuel which allows a continuous operation of the appliance, as consequence
the heating all over the night is not possible.
Variety
Beech
Oak
Elm
Poplar
Larch*
Spruce*
Scots pine *
ATTENTION : the continuous and protracted use of aromatic wood (eucalyptus, myrtle etc.) quickly damages the cast iron parts
(cleavage) of the product.

9. LIGHTING

ATTENTION: never light for any reason if the installation is not completely full of water in order to avoid a serious damage of
the whole structure. IABSOLUTELY DO NOT LIGHT THE FIRE IN THE THERMO-FIREPLACE IN THE TOTAL OR PARTIAL
ABSENCE OF WATER (NOT EVEN FOR CHECKING), AS IT COULD BE IRREMEDIABLY RUINED. IN SUCH CASE THE
WARRANTY ON THE APPLIANCE IS VOIDED.
WARNING: After the first ignition you can smell bad odours (owing to the drying of the glue used in the garnitures or of the paint) which
disappear after a brief using of the appliance. It must be ensured, in any case, a good ventilation of the environment. Upon the first
ignition we suggest loading a reduced quantity of fuel and slightly increasing the calorific value of the equipment
To perform a correct first lighting of the products treated with paints for high temperature, it is necessary to know the following information:
the construction materials of the involved products are not homogeneous, in fact there are simultaneously parts in cast iron, steel,
refractory material and majolica;
the temperature to which the body of the product is subject is not homogeneous: from area to area, variable temperatures within the
range of 300°C - 500°C are detected;
during its life, the product is subject to alternated lighting and extinguishing cycles in the same day, as well as to cycles of intense use
or of absolute standstill when season changes;
the new appliance, before being considered seasoned has to be subject to many start cycles to allow all materials and paints to
complete the various elastic stresses;
in detail, initially it is possible to remark the emission of smells typical of metals subject to great thermal stress, as well as of wet paint.
This paint, although during the manufacture it is backed at 250 °C for some hours, must exceed many times and for a given period of
time the temperature of 350 °C before becoming completely embedded in the metallic surfaces.
Therefore, it is extremely relevant to take these easy steps during the lighting:
1. Make sure that a strong air change is assured in the room where the appliance is installed.
2. During the first starts, do not load excessively the combustion chamber (about half the quantity indicated in the instructions manual)
and keep the product continuously ON for at least 6-10 hours with the registers less open than the value indicated in the instructions
manual.
3. Repeat this operation for at least 4-5 or more times, according to your possibilities.
7197130s - IT-EN-DE-FR
O, therefore it is not suitable to be burnt.
2
Kg/mc
750
900
640
470
660
450
550
*
RESINOUS WOOD NOT SUITABLE FOR THE BURNING
kWh/kg
20%
moistness
4,0
4,2
4,1
4,1
4,4
4,5
4,4
21

Publicité

Table des Matières
loading