FAULTS

Faults table

When you have any doubts about whether your appliance is working properly you should not
immediately assume that it is defective. We recommend that you should in any case check the
points in the following table.
Symptom
The appliance emits a slight
odour when used for the first
time.
The appliance does nothing;
the lighting does not come
on.
Temperature inside the
appliance too high or too low.
Water runs from the
refrigerator.
Appliance makes a noise.
The LED lighting does not
work.
Ice building up.
Note
It is normal for the cooling circuit to make gurgling or expansion noises.
Possible cause
New appliance.
Plug not in socket.
Thermostat off.
Thermostat setting incorrect.
The door seals are dirty or the
seals are damaged.
Defrost water drain clogged.
Incorrect positioning of food
in the appliance.
There is an object against the
appliance.
LED-lamp faulty.
Door freezer compartment not
closed properly.
Freezer compartment is not
periodically defrosted.
The door seals are dirty or the
seals are damaged.
Solution
This is normal and disappears
when the appliance starts
cooling.
Insert the plug in the socket.
Adjust the thermostat to the
correct setting.
Adjust the thermostat
properly.
Clean the door seals. Call
the service centre if the door
seals are damaged.
Clean defrost water drain (see
"Defrost").
Place foods in the proper
manner in the appliance.
Remove the object.
Call an authorized service
technician. Do not attempt to
replace the LED lighting by
yourself.
Make sure that the door is
closed properly.
Defrost the freezer
compartment to remove the
ice.
Clean the door seals. Call the
service centre if the door seals
are damaged.