2.2.2 Periodic transmission

The product allows the measurement and the periodic transmission of the values of the sensors according to the following diagram:
FR
EN
No
The settings associated with this mode of operation are:
• The transmission period (register 301).
• The configurations of the different digital inputs (registers 320 to 323).
A complete list of the registers can be found in paragraph 3.4.
E.g.:
Register
S301
S320
S322
S321
S323
In this example inputs TOR1 and TOR4 are in periodic mode while TOR3 is in event mode.
Period
reached?
Yes
Send frame 0x40
Value encoding
Decimal
Hexadecimal
Hexadecimal
Hexadecimal
Hexadecimal
Product in standby
Change on
digital input
?
Counting
event
Value
Résults
6
Periodic mode with a period of 6x10min = 60 minutes
0x73
Input TOR1 configuration:
• Periodic mode
• Detection of high and low edges
• Waiting* period of 1 second
0x00
Input TOR2 configuration:
• Disabled
• No waiting* period
0xB4
Input TOR3 configuration:
• Event mode
• Detection of high edges only
• Waiting* period of 20 second
0x32
Input TOR4 configuration:
• Periodic mode
• Counting of low edges only
• Waiting* period of 50 milliseconds
Yes
No