Installing The Unit; Countertop Cutout Dimensions - Hatco DHWBI Série Manuel D'installation Et D'utilisation

Masquer les pouces Voir aussi pour DHWBI Série:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

English

Installing the Unit

NOTE: Cut the opening for both the unit and the control
enclosure(s) before placing unit into the countertop
opening.
1. Cut the appropriate opening in the countertop. Refer to the
"Countertop Cutout" chart in this section.
2. Cut the appropriate opening for the control enclosure(s).
Refer to the "Control Enclosure Cutout Dimensions" chart
in this section.
3. Place ribbon putty gasket around the cutout edge of the
countertop. Make sure the ribbon putty gasket overhangs
the cutout edge or seal unit with silicone adhesive.
NOTE: A roll of ribbon putty gasket material is supplied with the
unit.
Countertop
Cutout edge of countertop.
Installing Ribbon Putty Gasket
4. Place the unit into the countertop opening.
5. Using a screwdriver, rotate the unit's EZ locking tabs
outward to secure the unit to the underside of the
countertop. Rotate as many tabs as needed to secure the
unit to the countertop.
EZ Locking Tabs
NOTE: The Hatco EZ locking tabs work on countertops
that have a maximum thickness of 3/16" (5 mm).
For countertops 3/16"–2" (5–51 mm) thick, use an
appropriate number of accessory thick counter adapter
brackets (HWB-MNT-REC ). Refer to the OPTIONS
AND ACCESSORIES section for Adapter Bracket
installation information.
6. Carefully trim and remove the excess ribbon putty material
from around the unit.
7. Install the control enclosure(s). Refer to the "Installing a
Remote Control Enclosure" procedure in this section.
Form No. DHWBISM-0519
Ribbon Putty Gasket
Countertop
EZ Locking
Tab

Countertop Cutout Dimensions

Model
Width (A)
44" – 44-1/8"
DHWBI-S2
(1116 – 1122 mm)
66" – 66-1/8"
DHWBI-S3
(1675 – 1680 mm)
88" – 88-1/8"
DHWBI-S4
(2234 – 2239 mm)
B
Countertop Cutout Dimensions
NOTE: Required minimum clearance below countertop cutout
is 17-3/16" (437 mm).
7
INSTALLATION
Depth (B)
14-1/16" – 14-1/4"
(357 – 362 mm)
14-1/16" – 14-1/4"
(357 – 362 mm)
14-1/16" – 14-1/4"
(357 – 362 mm)
Countertop
A

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Dhwbi-s sérieDhwbi-s2 sérieDhwbi-s3 sérieDhwbi-s4 série

Table des Matières