CAUTION
CAUTION
CAUTION : : : :
CAUTION
TO PREVENT THE RISK OF FIRE, THIS FIREPLACE MUST BE INSTALLED IN ACCORDANCE
WITH ACCEPTED TRADE PRACTICES AND IN COMPLIANCE WITH THE TECHNICAL REGULATIONS
THE INSTALLATION OF THIS APPLIANCE MUST COMPLY WITH CURRENT D.T.U. (French Code of Practice)
INSTALLATION BY A QUALIFIED TRADESMAN IS RECOMMENDED.
We strongly recommend that you take the time to thoroughly read and familiarize yourself with this manual
in order to obtain maximum enjoyment and satisfaction from your DEVILLE fireplace.
All local, national, and european regulations must be respected when using this appliance.
The nonobservance of the assembly, installation and operating instructions shall engage the liability of the

1 - FOREWORD

The "ready to install" fireplaces, models are to be
installed in the same manner as a wood burning
stove. The rules for installation are identical,
particularly as regards the following points :
The type and installation requirements of the
-
chimney flue compatible with this usage.
The connection of the fireplace to the chimney
-
flue.
Room ventilation.
-
Chapter 4 specifically concerns the "ready to
install" fireplace :
Installation against a backing wall.
-
Height adjustment.
-
Important, the "Ready-to-Install" fireplaces do not
allow the connection of hot air outlet ducts: the
safety of the environment can no longer be
ensured if the screens which protect the backing
wall are modified (pierced, moved).
The
following
chapters
recommendations for proper fireplace operation.
The building technical rules DTU 24-2-2 and 24.1
fully describe the specifications related to smoke
evacuation and fresh air intake requirements.
The "ready to install" fireplace C07368 is in
accordance with the French standard NF EN
13229.

2 - FIREPLACE CHARACTERISTICS

2.1 - Description

The
"ready to install" fireplaces, models
exclusively
wood-burning,
combustion, semi-open heating appliances, and are
designed to be installed against a backing wall
without any additional protection.
2.2 - Nominal heat output and reduced burn rate
autonomy
Nominal
Draught
output
10 kW
12 Pa
9,571 g/s
Nominal
heating
-
service : 10 kW.
www.pieces-de-poele.com
STIPULATED IN THIS MANUAL.
SPECIFICATIONS.
individual(s) concerned. The unit must not be modified.
provide
basic
grate-type
continuous
Flue gas
Smoke
mass flow
temperature
322 ° C
power
during
continuous
. Obtained with a draught of 12 Pa, for 1 hour
burning time, with a 3,3 kg load of hard unsplit
wood (oak, hornbeam...), i.e. approx. 2 logs
diameter 8 cm.
. To maintain this value, reload on to a bed of
embers of about 500 g, or 4 cm thick.
. The above value is the average value obtained
during the 1-hour test, draught damper (pipe
key) open, thermostat set on 8.
Slow burning :
-
Obtained with a 6 Pa draught, pipe key
closed, thermostat set on 0.
Reload on a bed of embers of about 0,3 kg (3
cm thick).
Burning time over 3 hours with an unsplit log
of hard wood of about 3,3 kg.
Burning time over 10 hours with 1 or 2 unsplit
logs (choose big diameter) of hard wood, total
weight 10 kg.
The use of the appliance in normal working
-
conditions allows to reach a maximal output
which must not be exceeded for safety reasons.
Ventilator output : 150 m
-
2.3 - Description (Fig. 1)
The fireplace consists of an insert, an exchanger
assembly and the trim.
The main elements which make up the insert are
identified in figure 1:
The combustion chamber is made of 4 mm
-
are
thick steel and the back of the insert is
doubled with a cast iron hearth plate.
A sheetmetal casing hides a cooling air
-
system around the combustion chamber.
The door is of cast iron and fitted with seals
-
ensuring air-tightness.
A control knob on the side will allow you to
-
choose the speed of the fire.
The thermostat knob allows to reduce the
-
excessive depression on some chimney
pipes.
A secondary air inlet is built into the upper part
-
of the glass door to keep it clean and to
provide better combustion on the wood.
13