Operation

Always turn your hood on before you begin cooking to establish an air flow in the kitchen.
Let the blower run for a few minutes to clear the air after you turn off the range. This will help
keep the whole kitchen cleaner and fresher.
Operate the hood as follows:
NOTE: At range hood start-up or after a power failure, a small icon (1) appears shortly
(for ± 2 seconds) on LCD screen; this is normal.
BLOWER ACTIVATION/SPEED LEVEL CHANGE/FILTER INDICATOR RESET
When blowers are OFF, press on this push button to turn ON the blowers at the last saved speed.
If there was no speed saved, the blowers will be set on LOW speed.
NOTE: When LOW speed is activated from OFF, the blowers start on MEDIUM speed for a very
short lapse of time, and then resume to LOW speed.
To change the blower speed, press on this push button again until the desired speed is reached
(from LOW to MEDIUM to HIGH speed to OFF). Each time a blower speed is activated, a rotating
blower icon appears on left side of LCD screen, with dot(s) under it (the rotation speed shows the
chosen speed: slow for LOW with one dot, faster for MEDIUM with 2 dots and fastest for HIGH
with 3 dots).
When blowers are on (no matter the speed level), press and hold this push button until the blower
icon disappears from the LCD screen; this will turn off the blowers and save the blower speed
chosen.
Heat Sentry™
This hood is equipped with a protective device that activates the blowers when an abnormally high
heat level is detected while the blowers are activated. During the Heat Sentry activation, this device
takes control of the blowers and set them on MEDIUM speed while all dots under the blower icon
blink. However, the lights can be still controlled. The blowers will remain on MEDIUM speed until
the heat is back to normal, they then return to the speed previously selected.
NOTE: When excessive heat is detected, Heat Sentry will shut off both blowers and lights while all
dots under the blower icon will blink faster. Both blowers and lights will remain off until the
ambient temperature cools down; the blowers will then start on MEDIUM speed (the lights
can be controlled again). The blowers will remain on MEDIUM speed until the heat is back
to normal, they then return to the speed previously selected.
FILTER CLEANING REMINDER
This icon appears on LCD screen 30 seconds after turning OFF the blowers when it is time to
clean hood and filters (refer to Cleaning and Maintenance on page 7). This happens every time
the blowers are turned OFF until the filter cleaning reminder has been reset. Once the cleaning is
done, reset the filter cleaning reminder by pressing on blower activation push button for 3 seconds
while the icon appears on LCD screen for 30 seconds.