Permanent installation
34
The appliance can be installed on a permanent
basis using window/wall Optional Accessory,
reference S1 RKZ 06009, available from your
supplier.
A hole must be made in the wall and the wall
accessory fitted in order to expel hot air.
Store the diffusion duct away and connect the air
expulsion duct to the accessory.
Only the transparent end section of the
accessory is used when air is to be expelled
through a window on a permanent basis. A
10.5-cm. diameter hole must be made in the
glass in order to fit the accessory.
N.B.
• Do not extend the hot-air expulsion duct more
than necessary (maximum length: 140 cm.).
• There must be a distance of at least 70 cm.
between the floor and the end of the duct.
• Do not bend the duct too sharply when
positioning it.
This can impede proper hot-air expulsion, which
may reduce cooling efficiency.