WARNING!
When employing the pump for pumping toxic, flammable, or radioactive
gases, please follow the required procedures for each gas disposal. Do not
use the pump in presence of explosive gases.
Switching on and Use of TV 801 Navigator Bolted
Flange
To switch on the TV 801 Navigator Bolted Flange it is necessary to
supply the mains. The integrated controller automatically recognizes
the interlock and start signals presence and start up the pump. The
first pump start up is in "Soft Start" mode. When the start up cycle is
finished, the "Soft Start" mode automatically is disabled, and the
following start ups are without the "Soft Start" mode. To re-enable
the "Soft Start" mode it must be activated by the suitable software
command (see the paragraph "RS 232/485 COMMUNICATION
DESCRIPTION" in the appendix "Technical Information"). The green
LED located on the TV 801 Navigator Bolted Flange base front panel
indicates with its flashing frequency the system operating conditions:

TV 801 Navigator Bolted Flange Switching off

To switch off the TV 801 Navigator Bolted Flange it is necessary to
remove the mains. The integrated controller immediately stops the
pump.
TV 801 Navigator Bolted Flange User Manual / 87-900-980-01
with no flashing: the pump is normally rotating;
slowly flashing (period of about 400 ms): the system is in ramp,
or in braking, or in Stop, or in "Waiting for interlock" status;
fast flashing (period of about 200 ms): error condition.