MACHINE TRANSPORT/PARKING

To transport/park the machine, proceed as follows.
1.
To turn off the machine, turn the main switch (26) to "0".
2.
Disconnect the power supply cable plug (21) from the electrical mains and place it on the holder.
3.
Lift the squeegee (46).
4.
Engage the positioning pin (24) and activate the machine transport/parking device (23a) to keep the brush/pad-holder lifted
(Fig. 3).
5.
While holding the machine in this position, drive it to the transport/parking area.
6.
In order not to drag the brush/pad on the floor and leave wet marks, when finishing working, remove the brush/pad-holder from
the deck by using the disengagement procedure (see the next paragraph), then place it on the front holder (33).
Brush/pad-holder removal
Remove the brush/pad-holder deck by performing the following procedure:
1.
Connect the power supply plug (21) to the electrical mains.
2.
To turn on the machine, turn the main switch (26) to "I".
3.
Turn the switch (52) to "I".
4.
Lift the brush/pad-holder deck (10) by prying the handlebar (2).
5.
Press the push-buttons (51) 3 times consequently, then wait that the brush starts and stop, thus disengaging from the drive
hub.
6.
Turn the switch (52) to "0".
7.
To turn off the machine, turn the main switch (26) to "0".
8.
Disconnect the power supply cable plug (21) from the electrical mains and place it on the holder.

TANK EMPTYING

An automatic float shut-off system (36) turns off the vacuum system when the recovery tank (27) is full.
The vacuum system shutdown, due to the recovery tank filling, is signalled by an increase in the vacuum system motor noise,
moreover the floor is not dried.
CAUTION!
If the vacuum system turns off accidentally (for example, when the float is activated because of a sudden
machine movement), to resume the operation: turn off the vacuum system by turning the switch (53) to "0", then
open the recovery tank cover (31) and check that the float inside the grid (36) has gone down to the water level.
Then close the recovery tank cover (6) and turn on the vacuum system by turning the switch (53) to "I" position.
When the recovery tank (27) is full, empty it according to the following procedure.
14
USER MANUAL
SCRUBTEC 343.2 - 9099644000
Figure 3