The SMS „A1:xxx" or „A2:xxx" (x = seconds) sets the
delay after which a reply SMS is sent after an output has
been activated. This can be helpful if you want to switch
something on or off and would like to measure the result
of this output control with one of the inputs of the STD32.
Therefore the new status after the switching of the output
is transmitted.
With the "PN:<4digit password>." command the password
can be changed. The password can include letters and
figures but no special characters are allowed. All letters
have to be in capital. The standard password (factory
setting) is the last 4 digits of the IMEI (see chapter SMS
Commands).
Four additional alarm numbers can be defined using C2: -
C5: commands. These numbers are allowed to set relay 1
by a call and they are informed via SMS in case of
event1,2 and start up. These numbers are not allowed to
send
If an alarm number is given in international format,
the number must start with '+'.
You can generate an extended clip list of several 100 clip
numbers. These numbers stored in the clip list are
allowed to switch relay 1. Use "CL:" to generate the clip
list and add further phone numbers. With "CD:" you can
delete a phone number from the list.
The texts of the event or start up SMS can be changed
with the commands "E1:<text1>", "E2:<text2>" and
"PT:<startup text>". The message length must not exceed
64 characters. Do not use command syntax inside a
message text. The '.' is the terminating character of
the text. Each new text must be sent in a separate
SMS.