Telic STD32 Mode D'emploi page 36

Masquer les pouces Voir aussi pour STD32:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Configuration SMS
A SMS with the text „O1:xxxxx" or „O2:xxxxx" (xxxxx =
seconds) configures the switching time of the relays. The
STD32 saves these settings so that they are still available
after the supply voltage has been restored.
If the switching time has been set to 0 by a configuration
SMS the corresponding relay switches permanently at
every call. If the relay has been active before it will
afterwards
In this case a SMS with the text „O1ON" from the
configured mobile phone switches the relay 1
permanently on. A SMS with „O1OFF"
switches off relay 1. Relay 2 is reacting accordingly to
SMS messages with „O2ON" and „O2OFF".
With a SMS with the text „I1:xxx" or „I2:xxx" (xxx =
seconds) you can configure the time the inputs have to be
activated before the STD32 sends out an alarm SMS.
A SMS with the text „V1:x" or „V2:x" (x = 1 or 0) can
change the polarity of the inputs. If x=1 an alarm SMS will
be sent in case the input has not been activated for the
configured time.
You can activate or deactivate the Start up SMS (START-
UP ALARM) with the SMS „S:x" (x = 1 or 0).
The SMS „R:" is setting the STD32 back to the factory
settings.
To get a feedback of the actual status of the inputs and
outputs
36
be
inactive
just
send
and
a
SMS
vice
versa.
permanently
with
„ST?".