Tool / battery protection system
The tool is equipped with a tool/battery protection
system. This system automatically cuts off power to
the motor to extend tool and battery life. The tool will
automatically stop during operation if the tool is placed
under one of the following conditions:
► 1 . Caution lamp
Caution lamp
Color
On
Green
Red
(tool) /
Red
Overload protection
If the tool or battery gets into one of the following situa-
tion, the tool automatically stops and the caution lamp
starts blinking in green:
The tool is overloaded by entangled weeds or
other debris.
The cutting tool is locked or kicked back.
The main power button is turned on while the
switch trigger is being pulled.
In this situation, release the switch trigger and remove
entangled weeds or debris if necessary. After that, pull
the switch trigger again to resume.
CAUTION:
If you need to remove the entan-
gled weeds on the tool or release the locked
cutting tool, be sure to turn the tool off before you
start.
Overheat protection for tool or
battery
If the tool or battery cartridge is overheated, the tool
stops automatically. When the tool is overheated, the
caution lamp lights up in red. When the battery cartridge
is overheated, the caution lamp blinks in red. Let the
tool and/or battery cool down before turning the tool on
again.
1
Status
Blinking
Overload
Overheat
(battery)
Over
discharge
Overdischarge protection
When the battery capacity becomes low, the tool stops
automatically and the caution lamp starts blinking in red.
If the tool does not operate even when the switches are
operated, remove the battery cartridge from the tool and
charge it.
Indicating the remaining battery
capacity
Press the check button on the battery cartridge to indi-
cate the remaining battery capacity. The indicator lamps
light up for a few seconds.
► 1 . Indicator lamps 2. Check button
Indicator lamps
Lighted
NOTE: Depending on the conditions of use and the
ambient temperature, the indication may differ slightly
from the actual capacity.
NOTE: The first (far left) indicator lamp will blink when
the battery protection system works.
9 ENGLISH
1
Off
Blinking
malfunctioned.
2
Remaining
capacity
75% to 100%
50% to 75%
25% to 50%
0% to 25%
Charge the
battery.
The battery
may have

Publicité