To decrease the power level press key
− Three green LEDs
5
show positions one to three.
6
− The red LED
shows the Power position. The Power
position is only used if there are strong odours, or a lot
of smoke or vapour. Its use must be kept to a minimum
because of the large extraction of air in this position.
− The Power position automatically goes back to speed
three after 6 minutes.
− The motor has a thermal switch that switches the motor
off with overheating. After cooling the motor will switch
on again.

Determining the cause of overheating is re-
quired. This can be caused for example by a
pan fi re, the impeller motor being blocked or
an object getting in the exhaust opening and
causing it to be partly or fully blocked.
Auto-Stop
To avoid the extractor hood from staying on, the motor is
automatically switched off after 3 hours (only if in 3 hours
operation has not been changed). The extractor hood
lighting stays on.

2.3 Lighting

Turning the lighting on and off
Extra lighting (max. 300W) can be connected to the cooker
hood. To turn the lighting on or off press
The light works independent of the motor.

2.4 Programming recirculation (optional)

.
2
This programming function activates the replacement
indicator of the monobloc recirculation fi lter and the delay
time is changed.
Activating programming
− The motor must be switched off
− Press the
The following functions then operate:
− Replacement indicator of the monobloc fi lter is activated.
− The delay time is set to 30 minutes (instead of the default
Read paragraph 3.3 for more information about replacement
of the monobloc recirculation fi lter.
Deactivating programming
− The motor must be switched off
.
4
− Press
The delay time is again set to 10 minutes (instead of 30 min-
utes) and cleaning indicator for recirculation is switched off.
– 36 –
If recirculation is selected programming must
take place once.
and the
2
3
seconds until the red LED fl ashes 5 times.
After a set time a red indicator light on the appliance
shows that the monobloc fi lter must be replaced.
10 minutes).
Use the delay time of 30 minutes so the
cooking odours can be properly removed in
the monobloc fi lter.
and
at the same time for 3 seconds until
2
3
the 3rd green LED fl ashes 3 times.
keys at the same time for 3

Publicité

Table des Matières
loading