Illumination
To activate the lights press button ⑥. The lights
will switch on at full power.
Lighting can be activated independently from the
motor.
Recirculation (option)
If recirculation has been chosen, this is to be
programmed
one
time.
activates the cleaning indication of the Monoblock
recirculation filter and changes the switch-off
delay time.
Programme (do the programming with the
motor switched off):
Simultaneously press the + and the – keys for 5
seconds until the red LED flashes 5 times. The
following functions have now been enabled:
• The run-out time has been set to 30 minutes
(instead of the default 10 minutes). Make use
of the 30 minutes run-out time.
• The cleaning indicator for the Monoblock r cir-
culation filter has been set to 200 operating
hours.
• The red LED will light up after 200 operating
hours. This indicates that the Monoblock recir-
culation filter needs cleaning
Deactivate the programming (do the deactivate
programming with the motor turned on):
Simultaneously press + and – for 5 sec. until the
third green LED flashes 3 times. Attention! This
is not recommended for a cooker hood with
recirculation.
Programming the remote control
The remote control for hood and hob are
preinstalled and ready for use. Only when te
remote control needs to be reprogrammed
(interaction with other controls)act as in the
following.
Determine the code used:
Simultaneously press on/off + the key with the
sun. The lamp flashes as well as the selected
code (there are 10 code options in total).
Change the code:
a. Simultaneously press on/off + the key with
the sun for 3 seconds until the lamp is flash-
ing. After this the lamp as well as the selected
code will flash. Repeat this step until you have
reached the required code (there are 10 code
options in total).
b. Simultaneously press + lamp of the roof cover
control until the second green LED is blinking.
c. Press the key with the sun on the remote con-
This
programming
trol within 10 seconds to confirm the settings.
The cooker hood and the remote control are
now in line with each other.
Change the batteries:
• For changing the batteries unscrew the plastic
cover, remove the old batteries and insert the
new ones. Pay attention to the polarity marking
given in the battery compartment (figure 4).
• Empty batteries are not to be disposed of in
the household refuse, but they are to be hand-
ed in as chemical waste.
NOVY key:
You can switch on the ambient lighting using the
NOVY key (figure 5).
Technical information:
- Power supply: (2xAAA) batteries
- Frequence: 433.92Mhz
- Numbre of codes: 10
- Worktemperature: 0-50°C
- Dimensions: 110 x 50 x 19mm
Maintenance
Grease filter
The cooker hood contains 2 or 3 metal grease
filters, dependent on the type number.
Grease filter indication:
------------------------------------------------------
Indication: 4 flashing LEDs
------------------------------------------------------
After 20 cooking hours, the 4 LEDs will start to
blink during 5 minutes, this indicates that the
grease filter has to be cleaned. When replacing
the cleaned filter, you have to reset the hood by
pushing the – button during 5 seconds. If you
don't reset, the LED lights will continu blinking.
We advise you to clean your filter twice a month
for an optimal operation.
EN 21