TIPS & TROUBLESHOOTING
• Install energizer where it can get plenty of sunlight.
• Keep solar panel surface clean - periodically use a so cloth with water and a
mild detergent.
• Test voltage on the fence using a Gallagher Fence Volt Meter (G50301).
Problem
Indicator fl ashing red
Indicator fl ashes red
twice when turned on
then stops
No voltage on fence
Solu ons
Ensure energizer is ge ng enough sun
Turn energizer OFF for 3 days, leave in the sun
to charge ba ery.
Remove ba ery and use a 6 V 1.2 A charger to
charge ba ery.
Perform above steps
Replace ba ery
Check energizer isn't faulty;
-
disconnect from fence and earth
-
measure across fence and earth terminals
with a Gallagher Fence Volt Meter
-
if less than 5 kV return energizer for service
-
if more than 5 kV the fault is with the fence
or earth system.