Leica TPS1100 Professional Série Manuel D'utilisation page 132

Tacheometre ou station total positioning system
Table des Matières

Publicité

Distancemètre intégré (Laser visible), suite
Plaques signalétiques
6
10
M ax. em i t t ed Pow er :
Puissance de sortie max. :
Em i t t ed W avel enght :
Longueur d'onde :
St andar d appl i ed
Norme appliquée :
12
IEC60825-1 : 1993-11 + Am1 : 1997-09 + Am2 : 2000
21
26
45
84
92
Type: TCR....
+Reflectorless Ext. Range
03
Power: 12V/6V ---, 1A
Leica Geosystems AG
CH-9435 Heerbrugg
Manufactured: ......
Made in Switzerland
This laser product complies with 21CFR 1040
as applicable.
This device complies with part 15 of the FCC
Rules. Operation is subject to the following two
conditions: (1) This device may not cause harm-
ful interference, and (2) this device must accept
any interference received, including inter-
ference that may cause undesired operation.
Avis de sécurité
0. 95m W c. w .
4.75mW
620- 690nm
620-690nm
:
EN60825- 1 : 1994- 07
I EC825- 1 : 1993- 11
......
Art.No.
S.No.
......
A V O ID E X P O S U R E
L a ser ra diation is em itte d
fr om th is ap ertu re
132
Divergence des
0.15 x 0.35 mrad
rayons:
Durée d'impulsion: 800 ps
Puissance de
4.75 mW
sortie max.:
Puissance
59.4 mW
d'impulsion max.:
Incertitude de
± 5%
mesure:
TPS1100 - Mode d'emploi 2.2.0fr
rayon
infrarouge
sortant