Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 25

Assembly

Please fold out the inside cover of your user manual for a graphic illustration of the assembly process.
Assembly of changing table heater with pedestal
1. Insert the 5 feet (B) into the foot connector system (A) as shown in fig. A1.
2. Place the foot cover (C) on top (fig. A2).
3. Insert the lower attachment tube (D) into the opening (fig. A3).
4. Fix the lower attachment tube in position by inserting the plastic screw (E) from below (fig. A4).
5. Slide a cable holder (G) over the lower attachment tube (fig. A5).
6. Connect the middle attachment tube (H) with the groove to the lower attachment tube as shown in fig. A6 and turn the middle
attachment tube until the holes in both tubes align.
7. Fix the middle attachment tube into place using the supplied screw (H) and a Philips screwdriver.
8. Slide the remaining cable holder (G) over the middle tube and connect the upper attachment tube (I) to the middle attachment
tube (fig. A7). Fix the upper attachment tube in position using the supplied screw and a Philips screwdriver.
9. Remove the assembly plate from the unit as shown in fig. A8.
10. Place the changing table heater (J) on the pedestal and fix it in position with the plastic screw (F) (fig. A9).
11. Open the grey locking screw of the upper attachment tube (fig. A10) and set the changing table heater to the desired height
using the telescopic rod. Ensure that a minimum distance of 100 cm to the changing table is observed. Adjust the unit to the
desired height by closing the locking screw.
12. Secure the cable by pushing it into the cable holders (fig. A11).
13. Position the changing table heater in the desired location, out of reach of children and observing the specified minimum distan-
ces. Ensure that the pedestal is positioned securely on a level surface.
Note: For an installation with fewer than 5 feet (for example due to limited space), the user must ensure stability of the changing
table heater pedestal by other means. Never place a changing table heater with fewer than 5 feet freely in a room.
Wall-mounted assembly of changing table heater
1. Remove the assembly plate from the unit as shown in fig. B1.
2. Hold the wall bracket on the wall taking into account the minimum distances (fig. B2) and mark the drill holes with a pencil. Use
a spirit level to ensure the bracket is level.
3. Bolt the wall bracket to the wall (fig. B3) using the supplied screws and wall plugs (J).
4. Slide the changing table heater into the relevant grooves on the wall bracket (fig. B3).
5. Screw the changing table heater to the wall bracket (fig. B4) using the screws removed in fig. B1.
Safety instructions for wall installation:
The changing table heater must be mounted on the wall in a stationary and level position. It must not be mounted on
the ceiling!
The changing table heater must not be mounted on wood, plastic or other flammable materials or under plug sockets.
IMPORTANT! Minimum distances: The minimum distance between the heater and the changing table is 100 cm. A mi-
nimum distance of 35 cm between the heater and the ceiling must be observed at all times. The heater must be placed
at least 65 cm away from furniture and flammable materials. Fire hazard in case of non-compliance!
For installation in bathrooms or shower rooms, the regulations of the local utility company must be observed. The heater must
be positioned in such a manner that the pull switch cannot be reached from the bath or shower.
Never install the unit above a bath tub!
- 12 -

Publicité

Table des Matières
loading

Table des Matières